15 Perform emissions measurement
15 Perform emissions mea-
surement
–
The emissions measurement at the boiler is a legal
requirement and must be performed by qualified
personnel on a regular basis.
–
Contact the competent chimney sweep and your
heating installer for more information.
–
When performing the emission measurement, the
chimney sweep function of the boiler control must
be used.
Chimney sweep measurement release
The chimney sweep function is available in the boiler
operating mode screen
Notes on chimney sweep measurement release
–
May only be performed by qualified personnel.
–
Do not open the boiler door during the mea-
surement.
–
Ensure sufficient heat removal for the boiler (e.g.
energy removal to buffer store or heating circuit).
–
The removal of heat is increased by opening the
heating circuit mixer and by switching on the hea-
ting circuit pumps.
Start of the chimney sweep measurement release
►
Press the
button.
Ä
The prerequisites for a measurement release
are tested.
Fig. 2-57
►
As soon as
Measurement enable
appears in the
status bar, the measurement can be started.
–
The chimney sweep measurement release
remains active for a period of 40 min., and before
this period expires, a message allowing extension
of the period by increments of 30 min in each case
is displayed.
–
To abort the function prematurely, switch to a dif-
ferent boiler mode.
15.1 Emission measurement for external
boilers
If necessary, use the menu
output test heating circuit
to carry out the emission measurement on an
external boiler. In this menu, the electrical outputs for
the remote boiler, 3-way motor valve as well as for the
heating circuit pump and heating circuit can be swit-
ched on/off manually.
16 Filling the pellet store
Switch off the boiler before filling
i
For safety reasons, switch off the boiler 15
min. before filling (blowing in) the pellet store.
By use of the item
House connection box for
pellet filling
(item no. 6678) this is done auto-
matically.