7 Electrical connection
7.6.1 Connecting auger motor
►
Connect the cable as shown in the terminal area
of the motor.
Abb. 2-60: Connect the cable in the motor terminal area
A3:X2,
and A4:X2
Auger motor
Cable
L1
V1
black
L2
U1
brown
L3
W1
grey
PE
PE
yellow/green
For power elements A3 and A4 see inside of boiler
cabinet door
7.6.2 Connecting the safety switch
►
Connect the safety switch
1
according to the dia-
gram in the terminal area of the auger motor
2
.
Abb. 2-61: Direct extraction auger
Connection in motor terminal area
Abb. 2-62: Connect the safety switch in the motor terminal area
7.7 Sensor resistance table
Type
KTY 81-110 PT100 PT1000 KTY 81-210
Tolerance
± 3 %
± 0.7 % ± 1 %
± 3 %
°C
Ohm
Ohm
Ohm
Ohm
-20
684
92.16
922
1367
-10
747
96.09
961
1485
0
815
100
1000
1630
10
886
103.9
1039
1772
20
961
107.79
1078
1922
25
1000
109.74
1097
2000
30
1040
111.69
1117
2080
40
1122
115.54
1155
2245
50
1209
119.4
1194
2417
60
1299
123.24
1232
2597
70
1392
127.07
1271
2785
80
1490
130.8
1309
2980
100
1696
138.5
1385
3392
120
1915
146.06
1461
3617
140
2124
153.58
1536
4186
150
2211
157.31
1573
4280
160
-
161.04
-
-
170
-
164.76
-
-
180
-
168.46
-
-
190
-
172.16
-
-
Installation manual
maximus L
39
Содержание maximus L 150
Страница 16: ...Front Abb 2 10 Side view Abb 2 11 3 Technical requirements 16 Installation manual maximus L ...
Страница 44: ...11 Annex 11 1 Mounting boiler covers overview Abb 2 72 Abb 2 73 11 Annex 44 Installation manual maximus L ...
Страница 50: ...11 Annex 50 Installation manual maximus L ...
Страница 51: ...11 Annex Installation manual maximus L 51 ...