6 Installation
6.1.5 Connect burner and heat exchanger
hydraulically
►
Make piping between the two connections.
(Connection is not pre-fabricated).
Fig. 2-24: Connect the water circuit
6.2 Install the hot air fan
►
Install hot air fan
1
in the ignition tube.
►
Connecting to terminals:
Fan
A1:X7
Heating element
A1:X4
►
The cable is pre-routed in ducts 3 and 2
.
Fig. 2-25: Install the hot air fan
6.3 Mount feeder grate drive
►
Mount drive unit
1
(plate, housing, motor/gearbox)
to the burner with 4 pcs hexagonal screws.
►
Mount connecting rod
2
with washer and circlip on
the bolt
3
.
►
If necessary (to turn the crank), remove motor/-
gearbox
4
.
►
Connect motor to
X4.7-X4.9
; the cable is pre-rou-
ted in ducts 3 and 2
Fig. 2-26: Mount feeder grate drive
Connect the feed grate motor
►
Connect the pre-routed cable as shown in the ter-
minal area of the motor.
Fig. 2-27: Connect the cable in the motor terminal area
Operation manual
maximus
19