4.5 Technical specifications
maxi
mus
150
200
250
300
Wood chips output
[kW]
149
201
240
-
Pellets output
[kW]
149
201
250
299
Boiler class (acc. to EN 305:5
2012)
5
5
5
5
Dimensions
Width
[cm]
189
189
189
189
Height incl. adjustable feet
[1]
[cm]
207
207
207
207
Depth with ID fan
[cm]
222
222
222
222
Burner insertion dimension
(width)
[cm]
90
90
90
90
Heat exchanger insertion dimen-
sion (width)
[cm]
110
110
110
110
Minimum room height
[2]
[cm]
275
275
275
275
Weight
Burner weight
[kg]
700
700
700
700
Hat exchanger weight
[kg]
950
950
950
950
Total weight
[kg]
1650
1650
1650
1650
Water side
Water content
[l]
565
565
565
565
operating temp.
[°C]
70 - 90
70 - 90
70 - 90
70 - 90
Maximum permissible tem-
perature
[°C]
90
90
90
90
Max. permissible operating pres-
sure
[bar]
3
3
3
3
Min. return flow temperature
[°C]
60
60
60
60
Connection Boiler inflow/Boiler
return flow
[“]
G 2“ OT
G 2“ OT
G 2“ OT
G 2“ OT
Drain connection
[“]
1”
1”
1”
1”
Connection for thermal overload
protection
[“]
G 1/2“ OT
G 1/2“ OT
G 1/2“ OT
G 1/2“ OT
Electrical systems
Electrical connection
400 V AC, 50 Hz,
16 A, 3P+N+PE
400 V AC, 50 Hz,
16 A, 3P+N+PE
400 V AC, 50 Hz,
16 A, 3P+N+PE
400 V AC, 50 Hz,
16 A, 3P+N+PE
Fuel
Fuel - wood chips
Wood chips in accordance with EN ISO 17225-4, classes A1, A2, B1, B2;
sizes P16S and P31S; water content max. 40% (M40)
Fuel - wood pellets
Wood pellets according to EN ISO 17225-2
Flue gas side
Flue gas pipe diameter
[cm]
25
25
25
25
Height of flue gas pipe
[1]
[cm]
207
207
207
207
Minimum draught requirement
[3]
[Pa]
5
5
5
5
Maximum flue gas temperature
[4]
full load
[°C]
140
140
140
140