Technical Specifications
SolarEdge Installation Guide for Three Phase Inverters
– EU – Version 1.5
82
SE7k SE8k SE9k SE10k SE12.5k
Input
Recommended Maximum DC Power (Module STC)
7700
8800
9900 11000
13000
W
Transformer-less, Ungrounded
Yes
Maximum Input Voltage
950
Vdc
Nominal DC Input Voltage
750
Vdc
Maximum Input Current
14
15.5
20
18.5
22
Adc
Reverse-Polarity Protection
Yes
Ground-Fault Isolation Detection
600 kΩ Sensitivity
Maximum Inverter Efficiency
98
%
European Weighted Efficiency
97.7
97.6
97.6
97.5
97.4
%
Nighttime Power Consumption
< 2.5
W
Standards Compliance
Safety
IEC-62103 (EN50178), Draft IEC-62109, UL1741
Grid Connection Standards
VDE 0126-1-1, AS-4777, RD-1663, DK 5940, IEEE1547, NEC
Emissions
IEC61000-6-2, IEC61000-6-3, IEC61000-3-11,
IEC61000-3-12, FCC part15 class B
WEEE, RoHS
Yes
Installation Specifications
AC Output
Cable Gland - diameter 13-18
mm
DC Input
MC4 compatible
Maximum Installation Height
2000
m
Dimensions (W x L x H)
540 x 315 x 260
mm
Weight
32
kg
Operating Temperature Range
-20 – +60
°C
Cooling
Fan (user replaceable)
Protection Rating
IP65 – Outdoor and Indoor
Bracket Mounted (Bracket Provided), Optional Attachable Cabling Duct (EU), Integral DC Switch (US)