Solarbayer GmbH
11
MOUNTING INSTRUCTION
High capcity collector PremiumPlan
tighten the collector carrier rail to
the base rail with M 8x60 screws
Fasten the telescope rail to the
base rail with M 8x60 screws
telescope rail connection with
M 8x60 screws
flat roof stand-kit for 2 collectors
flat roof stand-kit for 3 collectors
inclination
α
min. 40°
45°
max. 58°
collector height
a
2,24m
2,24m
2,24m
overall height
b
1,44m
1,58m
1,90m
basic length
c
1,72m
1,58m
1,19m
distance between rows
d
4,71m
5,18m
6,21m
weight against wind load (kg/m² collector surface area)
according to DIN 1055-4
Gebäudehöhe
Ohne Bodenfreiheit
Mit Bodenfreiheit >30cm
0 bis 8 m
80 kg/m²*
60 kg/m²*
8 bis 20 m
130 kg/m²*
100 kg/m²*
* in effect for locations under 600 m sea level and wind speeds between 100km/h and 130km/h
Check static of the substructure before mounting
collector arrangement:
Calculating the clouding:
vertical angle of the sun 17° on 21.12.
Special solution:
mounting with a flat roof stand-kit
collector
collector
collector
collector
collector
collector
carrier rails
collector
carrier rails
base frame
base frame