Electrical documentation
64
© Solarbayer GmbH [210205]
13.3
Connection diagram control board
X1 – 230 V AC – Power line – Phönix RM 5,08
Pin
Signal
Function
1
L
Mains voltage
2
N
Neutral line
3
PE
Ground conductor
X2 – 230 V AC Relay output return pump – Phönix RM 5,08
Pin
Signal
Function
1
L-RO01
Mains voltage return pump
2
N
Neutral line
3
PE
Ground conductor
X3 – 230 V AC Relay output return flow mixer – Phönix RM 5,08
Pin
Signal
Function
1
L-RO02
Mains voltage return mixer OPEN
2
L-RO03
Mains voltage return mixer CLOSE
3
N
Neutral line
4
PE
Ground conductor
X5 – Analog input lambda sensor – Phönix RM 3,5
Pin
Signal
Function
1
AI5+
Lambda
2
AI5–
Lambda sensor –
3
12 V AC1
Sensor heating 12 V AC shifted
4
12 V AC2
Sensor heating 12 V AC
X7 – Analog input return flow temperature – Phönix RM 3,5
Pin
Signal
Function
1
AI02
Return flow temperature
2
AGND
AGND
X8 – Analog input buffer bottom temperature – Phönix RM 3,5
Pin
Signal
Function
1
AI01
Buffer bottom temperature
2
AGND
AGND
X9 – Analogue input buffer top temperature – Phönix RM 3,5
Pin
Signal
Function
1
AI00
Buffer top temperature
2
AGND
AGND
X10 – 230 V Analog output secondary air damper – Phönix RM 3,5
Pin
Signal
Function
1
+24 V
+24 V
2
AO2
secondary air damper
3
GND
GND
X11 – 230 V Analog output primary air damper – Phönix RM 3,5
Pin
Signal
Function
1
+24 V
+24 V
2
AO1
primary air damper
3
GND
GND
Содержание BioX 15
Страница 1: ...Operating Instructions Wood log boiler Wood log boiler BioX 15 45...
Страница 76: ...Note 76 Solarbayer GmbH 210205 17 NOTE...