Put the side covers with the 4
elevating screws in the right position.
Check though the clearance of the
filling shaft door and the distance
between boiler body and the covers.
Following fix the nuts for the vertical
attitude. (look at point 20, number
)
Mountation of the exhaust blower
Take the exhaust blower out of the
package.
Remove the bottom holding bow
.
Slack the top holding bow until the
end of the thread and clip the blower
on the connection of the smoke
tube.