background image

Pro-Logix Battery Charger USER’S MANUAL

OPERATION AND MAINTENANCE 

How Your 

SOLAR Pro-Logix

Battery Charger Works

Your SOLAR Pro-Logix battery charger uses an advanced high-frequency conversion
technology, which replaces the transformer found in most other battery chargers. This
technology enables a compact and portable form of conversion with excellent voltage
protection as well as overload and short circuit protection.

Your SOLAR Pro-Logix battery charger is designed with built-in microprocessor
control designed for use in a 120 Volt AC environment. The charger converts AC
power to DC charging currents through switch mode technologies at frequencies
between 40 kHz to 60 kHz. All SOLAR 
Pro-Logix battery chargers are fully automatic
through all four operating phases and feature “Push and Go” One-Touch Control, such
that once the charger is hooked up to the battery and a battery size is chosen, no
additional input is needed from the operator.

When your SOLAR Pro-Logix battery charger is first connected, the microprocessor
will automatically assess the charger/battery connection and then diagnose the
battery’s condition, starting with a temperature assessment. Then, it will go through
battery-voltage diagnostics, lighting one of three warning LEDs if a specific
problematic conditions exist:  if the battery voltage is below 4.5V, reflects a short
circuited connection (clamps touching, etc.), or indicates a reverse polarity connection.
If any of these conditions exist, the corresponding LED warning will blink and the
charger will not begin the charging process.

Once a 12 Volt battery is properly connected and no problematic condition exists,
your SOLAR 
Pro-Logix battery charger will automatically initiate its unique, Quad-
Phase charging cycle, utilizing exclusive “Active Filtering Technology” to deliver an
ideal charge. 

Phase 1 – Energizing: The charger will begin with 5 minutes of low Amp charging,
during which the microprocessor will automatically diagnose various protection modes
of the battery. In this phase, the charger safeguards against high current surging
through the battery and calculates the optimal charging rate for the subsequent
charging phases. During this phase, the LED corresponding to Phase 1 will blink.

Note: During this stage of the operation, if required, the charger will attempt to
desulphate the battery plates and prepare the battery for Phase 2 – Charging (the
charger diagnoses and performs the desulphation routine automatically if
necessary – no input is needed from the operator). 

Phase 2 – Charging: Upon completion of Phase 1, the charger will automatically
commence Phase 2, Charging, during which the charger will apply a fast or bulk
charging mode to the battery. Through its constant pulsing current pump, the charger
fast charges the battery according to a pre-set voltage, while avoiding over-heating.
During this phase, the LED corresponding to Phase 2 will blink.

Phase 3 – Absorption: Upon completion of Phase 2, the charger will automatically
commence Phase 3, Absorption, during which the charger will slow its charge mode
to bring the battery to full charge. This is an important stage in the Quad-Phase
process during which the charger verifies that the charging energy has been
successfully transferred to the battery before the exercising phase is initiated. During
this phase, the LED corresponding to Phase 3 will blink.

Содержание Pro-Logix PL2208

Страница 1: ...age or explosion always shield eyes Read entire instruction manual before use WARNING Warning This product contains chemicals including lead known to the State of California to cause cancer birth defe...

Страница 2: ...ommon conductor which would be hazardous if the charger were plugged into an AC outlet Use extreme care while working within the engine compartment because moving parts may cause severe injury Read an...

Страница 3: ...p start or charge a frozen battery Important Safety Instructions Disconnect charger from AC source prior to connecting or disconnecting the battery Your battery charger is designed to charge rechargea...

Страница 4: ...Volt battery is properly connected and no problematic condition exists your SOLAR Pro Logix battery charger will automatically initiate its unique Quad Phase charging cycle utilizing exclusive Active...

Страница 5: ...osing the right charger for your specific needs will be best served by matching the charger that best corresponds to the batteries you plan to charge with the charger as illustrated in the chart below...

Страница 6: ...ing control in the charger to automatically shut itself down It will require restarting the power switch to reset the charger Output Short Circuit Protection The charger will immediately shut down the...

Страница 7: ...RED positive clamp to the positive battery terminal 2 Connect the BLACK negative clamp to the negative battery terminal 3 Ensure that the clamps are in good contact with the battery terminals This en...

Страница 8: ...as determined by Clore Automotive LLC In no event shall Clore Automotive LLC be liable for consequential or incidental damages Some states do not allow limitations on the length of the implied warran...

Страница 9: ...el producto que utiliza la bater a Al seguir todas las instrucciones y procedimientos de seguridad se reducir el riesgo de accidentes Trabajar cerca de bater as de plomo cido puede ser peligroso Las...

Страница 10: ...te un anillo u objeto similar y as provocar quemaduras graves NUNCA arranque o intente recargar una bater a congelada INSTRUCCIONES IMPORTANTES DE SEGURIDAD Desconecte el corcel de la fuente de C A an...

Страница 11: ...condiciones problem ticas espec ficas si la tensi n de la bater a es inferior a 4 5 V refleja una conexi n en cortocircuito pinzas en contacto etc o indica que la conexi n tiene la polaridad invertida...

Страница 12: ...Logix adecuado Cada cargador de bater as SOLAR Pro Logix est dise ado para una carga ptima de bater as de un rango espec fico de capacidades Para seleccionar el cargador adecuado para sus necesidades...

Страница 13: ...te de C A al nivel ptimo apagarse en forma autom tica al disminuir la tensi n de entrada de CA Protecci n contra tensi n de CD Si el cargador se conecta a una bater a de 24 voltios o con polaridad inv...

Страница 14: ...n lugar bien ventilado durante su funcionamiento NUNCA use un cargador de bater as junto a o cerca de materiales inflamables NUNCA intente cargar una bater a congelada Los cargadores de bater as SOLAR...

Страница 15: ...unidad presione el bot n selector de capacidad de bater a hasta que ning n indicador LED quede encendido la unidad estar apagada y desenchufe el cargador del tomacorriente de CA recordando tirar siemp...

Страница 16: ...za a toda otra garant a ya sea oral escrita expl cita impl cita o estatutaria entre otras cualquier garant a impl cita de comerciabilidad o idoneidad para un fin determinado Para obtener el servicio t...

Страница 17: ...isque d accident Il peut tre dangereux de manipuler des batteries au plomb acide En effet elles d gagent des gaz explosifs pendant le fonctionnement normal et le rechargement Veuillez lire et suivre a...

Страница 18: ...tal ce qui pourrait entra ner des br lures graves N essayez JAMAIS de survolter ni de charger une batterie gel e IMPORTANTES INSTRUCTIONS RELATIVES LA S CURIT D brancher le chargeur de la source de c...

Страница 19: ...ns DEL s allumera si la tension de la batterie est inf rieure 4 5 V si le branchement est court circuit les pinces sont en contact etc ou si le branchement est en polarit invers e Pour chaque situatio...

Страница 20: ...eur qui convient Les chargeurs Pro Logix de SOLAR sont tous con us pour charger de mani re optimale une certaine plage de tailles de batteries Pour choisir un chargeur adapt vos besoins pensez aux bat...

Страница 21: ...a tension de courant alternatif re ue au niveau optimal fermant automatiquement quand la tension d entr e c a diminue Protection voltm trique c c Si le chargeur est reli une batterie 24 V ou en cas de...

Страница 22: ...ants Assurez vous que le chargeur de batterie soit plac dans un lieu bien a r pendant l utilisation N utilisez JAMAIS un chargeur de batterie proximit de mat riaux combustibles N essayez JAMAIS de cha...

Страница 23: ...arg e placez le principal interrupteur c a en position arr t pour teindre l appareil appuyez sur le programmateur de la taille de batterie jusqu ce qu aucun voyant DEL ne s allume L appareil est d sor...

Страница 24: ...ande ou l ad quation un usage particulier de ce produit Pour b n ficier d un service dans le cadre de cette garantie veuillez retourner le chargeur de batterie Pro Logix de SOLAR au point de vente acc...

Отзывы: