2. Specifications
5
2.4 dimensions
Unit
:
mm
MODEL: ATMOS AIR 270
Model
Heating capacity(
)
kW
Water tank capacity(L)
Power input(
)
kW
Running current(A)
Power supply
Compressor Number
Compressor
Rated outlet water Temp.
Air volume(
)
3
m /h
Nosie(
)
dB(A)
Water inlet/outlet size(inch)
*Auxiliary E-heate (
)
r kW
Net dimensions(mm)
Shipping dimensions(mm)
Net weight(kg)
ATMOS AIR 270
3.6
0.94
4.3
240V~/50Hz
1
rotary
60
450
48
3/4
1.5
See the drawing of the units
See package label
See nameplate
2. Specifications
2.5 performance parameters
6
Work range
(1).Ambient temperature is -5
℃
~43
℃
(Heat Pump)
Measurement conditions:
Instant heating: Ambient temperature20
℃
/15
℃
,Water inlet 15
℃
Water outlet 55
℃
,
Operating parameters
The range of the operating water pressures: 0.15~0.7MPa
FREEZE PROTECTION
The water heater has a freeze protection system. The freeze protection
system will protect thewater heater from damage, by preventing ice
forming in the waterways of the water heater, in the event of freezing
conditions occurring.
Φ
640
16.5
B
A
C
P&T valve
Over heating
protector
Electric heater
Drainpipe
98.5
D
E
Cold water
inlet
Hot water outlet
Condensation
water outlet
Magnesium
270
Model
A(mm)
B(mm)
C(mm)
D(mm)
E(mm)
ATMOS AIR 270
1955
1425
577
1195
1095
Содержание ATMOS AIR 270
Страница 1: ...Operation Installation Manual HEAT PUMP ...
Страница 36: ...NOTES ...
Страница 37: ...NOTES ...
Страница 38: ...NOTES ...
Страница 39: ...NOTES ...