3.Function presentation
3 minutes protection
If the unit stops and you re start the unit or turn it on by the manual switch, the unit will not
start to run again for approx 3 minutes. This is a protection feature to safe guard the
compressor.
In low ambient conditions the heating output decreases.
Heating capacity
Working conditions
Defrosting
In the heating mode the unit will defrost automatically, maximizing the heating efficiency
(Lasting 2 - 10 minutes)
.
The fan motor will stop running whilst the unit is defrosting
.
Water
pressure protection
temperature or
When the tank pressure reaches 0.85MP or when the tank
,
temperature reach 93 the P&T
valve will open automatically so as to force the pressure or decrease the temperature .
7
In order to use the unit correctly, please run the unit at environment temperature
-
5
℃
~43
℃
. The unit includes sophisticated electronic devices, prohibited to use water
8
4.1 Pipeline connection sketch
4. Installation
ATTENTION
Pipeline connection explanation
Installation of the water inlet or outlet pipes: The specification of the water inlet and
outlet thread is BSP3/4(internal thread).pipes must be heat-resistant and durable.
Installation of the pipe for P&T valve: The spec of the valve connecting thread is
BSP3/4(internal thread).After installation, it must be confirmed that the drainpipe
outlet is exposed in the air. When the flexible drainpipe is joined to the pressure relief
orifice of this valve, you must ensure that the flex
i
ble drainpipe is pointing downwards
and exposed in the air.
Water Inlet
Y-shaped Filter
Tap Water
Thermal expansion tank
(if required)
Barrel-drain
Drainpipe
Condensate Outlet
P&T Valve
Water Outlet
Notice:
Tempering valve required
Magnesium
ATTENTION: The P&T valve attached with the unit must be installed, fail to do so
Setup cannot affect the building structure and safety.
Notice:
A pressure realeasing
valve is
to be fitted in
the installation.
Spec of
P&T valve:
Pressure: 0.85MP
a
Temperature: 99
℃
will cause damage to the unit, and possible personal injury.
Do not use stainless steel fittings to connect directly with other metals to prevent
galvanic corrosion.
Drain the water
tank through the
drain valve at
the bottom part
of the unit.