9
4. Installation
4.2
As a rule, the unit is to be stored and/or transported in its shipping container in the upright
position and without water charge. For transport over short distance, and provided due care is
exercised, an inclination angle of up to 30 degree is permitted. Both during transport and
storage, ambient temperatures of -5
℃
to 43
℃
are permissible.
4.2.1 Transport using a forklift
When transported by a fork lift, the unit must remain mounted on the pallet. The lifting rate
should be kept to a minimum. Due to its top-heaviness, the unit must be secured against
tipping over. To prevent any damage, the unit must be placed on a level surface!
4.2.2 Manual transport
For the manual transport, the wooden pallet can be used for bottom part.
Using ropes or carrying straps, a second or third handling configuration is possible. With this
type of handling, care must be taken that the max.
Permissible inclination angle of 60 degree is not exceeded. If transport in an inclined
position cannot be avoided, the unit should be placed into operation one hour after it has been
moved into final position.
Transportation
CAUTION High center of gravity!
WARNING
For continued safety of this appliance it mustbe installed, operatedand
maintained in accordancewith the manufacturer'sinstructions.
If thewater supply pressure exceeds the rated pressure, a pressurereducing
valve is tobe fitted wheninstalling the unit.
The water may drip from thedischarge pipe ofthe pressure reliefdevice and that
this pipe mustbe left opento the atmosphere.
The pressure reliefdevice should beoperated regularly toremove lime deposits
and verify thatit is notblocked.
Adischarge pipe connectedto the pressurerelief device isto be installed in
acontinuously downward directionand in afrost-free environment.
Facilities fordraining and fillingof systems shall be provided wherethese
arerequired for servicing purposes. Thedrainage facilities, where fitted, shall beat
the owest point inthe closed circuit.
Air inlet
4. Installation
4.3 Installation space
Before installation, please ensure that you leave the space as shown below for maintenance.
Air outlet
Display
Barrier
500
≥
1000
≥
≥
300
Unit:mm
10
≥
600
500
≥
Содержание ATMOS AIR 270
Страница 1: ...Operation Installation Manual HEAT PUMP ...
Страница 36: ...NOTES ...
Страница 37: ...NOTES ...
Страница 38: ...NOTES ...
Страница 39: ...NOTES ...