42
| 12.0 Specifications
12.0 Specifications
Table 7: UPS Specifications
Parameters
Model Number: S4K5U6K5C
Rating
6000 VA/4800 W
DIMENSIONS, w x D x H, mm [in.]
Unit
430 x 574 x 217 [16.9 x 22.6 x 8.5]
Shipping
530 x 745 x 516 [20.9 x 29.3 x 20.3]
wEIgHT, kg [lb.]
Unit
60 [132.2]
Shipping
71 [156.5]
INPUT AC PARAMETERS
Nominal Operating Frequency
50 or 60 Hz (Factory default is 50 Hz)
Factory Default V ac
230 V ac
User-configurable V ac
220/230/240 V ac (Can be modified using included configuration program)
Operating Voltage Range without Battery
Operation
176–280 V ac
Maximum Allowable V ac
280 V ac
Input Frequency without Battery Operation
40–70 Hz
Input Power Connection
S4KPAD2-CEHWMBSC Standard (See “3.3 removable Power Distribution Box”)
OUTPUT AC PARAMETERS
Factory Default V ac
230 V ac
Output Connections
S4KPAD2-CEHWMBSC Standard (See “3.3 removable Power Distribution Box”)
Frequency
50 or 60 Hz, nominal
Wave form
Sine wave
Main Mode Overload
>200% for 5 cycles; 151– 200% for 1 second;
131–150% for 10 seconds; 105–130% for 1 minute
ByPASS PROTECTION LIMITS
Disable Bypass Operation
if input voltage exceeds ±15% of the nominal voltage
Re-enable Bypass Operation
if input voltage returns to within ±10% of nominal output voltage
Disable Bypass Operation
When the input frequency prevents synchronous operation
ENVIRONMENTAL REqUIREMENTS
Operating Temperature
0°C to +40°C [+32°F to +104°F]; See Table 8
Storage Temperature
-15°C to +50°C [+5°F to +122°F]
Relative Humidity
0% to 95%, non-condensing
Operating Elevation
Up to 1,000 m [3,281 ft.] at +30°C [+86°F] without derating
Audible Noise
<55 dBA @ 1 m [3.2 ft.] rear; <50 dBA @ 1 m [3.2 ft.] front & sides