硕飞科技
SHENZHEN SOFI TECHNOLOGY www.sofi-tech.com
User Manual
8
SP16 Series programmer
Automatic mode
Select the "Automatic Programming" page in the command bar on the left side of the main software
window. First set the operation content, and then click the "single program" button. The programmer
then performs the steps set in "Operational Content" to complete programming process of one device.
Typical steps:
➢
Program SPI FLASH (25 series): Erase
→
check space
→
program
→
check
➢
Program SPI FLASH (25 series, brand new blank device): Program
→
check
➢
Program I2C EEPROM (24 Series): Program
→
Verify
➢
Read device data and save it to file: Read
→
Verify
→
Save
Production mode
After clicking
“Production Programming” button, the programmer automatically detects the placement
and removal of the device
and automatically completes the steps in “Operational Content”. The software
pops up a message box to remind users to pick and place devices. It is convenient and quick to program
without using mouse or any buttons.
LED status for on-line programming mode
Power LED (PWR)
:
A long red light indicates that the power supply is normal, and a red flash indicates that the programmer has
detected a device short circuit or excessive current.