SP16  Series  programmer 

 

Controlled by ISP/ATE interface

 

This option can be used only in SP16-FX. When this function is checked, SP16-FX works in the automatic 

control mode and works with automatic machine. 

If this function is not checked, SP16-FX works in manual mode. 

Erase option

 

This feature is currently supported by SP16-F/SP16-FX and available for FLASH class devices only. 

In order to reduce time of erase options, it can be used to set operation mode when operation content box 

contains erase option. 

Forced Erase:

 Always erase the device in its entirety   

Non-empty erase: 

Perform erase operation when the device is not blank. The programmer will first perform 

a blank check on the device. The erase operation will be performed only if it is not blank. If the  device is 

already blank, the erase operation will not be performed. 

Device Type /Operation Content setting /Erase Option 

Device Type 

Operation Content setting 

Erase Option 

All blank FLASH devices 

program

check 

All non-blank FLASH devices 

erase

program

check 

Forced erase 

Blank  device  mixed  with  non-blank 

device 

erase

program

check 

Non-empty erase 

Note:

 When there is no "Erase" item in the action content box, the erase option does not need to be set 

and it will be disabled in gray. It is enabled only if there is an erase item in the action content. 

For other setting options, please refer to the help topic of FlyPro software. 

5. Disconnect the USB cable between computer and programmer after completing off-line data download, and 

then programmer can work independently from the computer. 

 

Off-line operation - manual mode 

The steps for the programmer to operate off-line are as follows: 

1. Power the programmer with the power adapter that came with the product. 

2. After the programmer is powered on, the internal off-line data will be checked to verify that the data is       

complete and accurate. 

      This takes 3 to 25 seconds. STA indicator will flash green if the test passes, indicating that the   

programmer has entered to off-line programming mode. STA displays a red flashing state if the test fails, i 

ndicating that there is no valid off-line data in the programmer, and off-line programming cannot be started. 

3. The programmer's STA indicator flashes green to indicate that it is waiting for the device to be placed. 

4. STA stops flashing and being orange indicates that the programmer has detected the device and is         

programming. 

5. STA displays green or red indicates that device is programmed. Green indicates successful, and red   

indicates failed. At the same time, the programmer begins to wait for the current device to be removed 

from   

ZIF Socket. If the buzzer prompt function is turned on, programmer will make sounds when programming   

is completed. 

6. After detecting the device removal, programmer repeats steps 3 through 5 to program next device. 

 

 

 

Содержание SP16 Series

Страница 1: ...grammer please read this manual carefully and operate the programmer correctly as required Failure to follow the instructions will result in damage to the programmer and no warranty service 深 圳 硕 飞 科 技 有 限 公 司 SHENZHEN SOFI TECHNOLOGY CO LTD WEB WWW SOFI TECH COM 硕飞科技 ...

Страница 2: ...Download Off line Data 10 Off line Operation Manual Mode 12 Off line Operation Automatic Control Mode 12 ATE interface definitions 12 LED status for off line programming mode 12 View Off line Data 13 Chapter 5 ISP Programming 14 Use ISP programming mode 14 ISP Interface 14 ISP cable 14 Target devices connections 15 ISP Power supply mode 16 Chapter 6 FlyPRO MCP multi machine control software 17 Fun...

Страница 3: ...vely prevent misplaced or destroyed device s effects on the programmer Programmer has a built in 32 bit high speed processor that provides high speed programming and precise timing Supports off line programming without connecting computers Has a large data memory built in that can supports up to 512Mbit device to program off line Note 1 Mass production programming mode automatic detection of devic...

Страница 4: ...aming Machine Support ATE Y N N programing speed Note 4 GD25Q16 SOP8 Off line P V 6S on line P V 7S W25Q128FV SOP8 Off line P V 47S on line P V 52S MX25L12845E SOP16 Off line P V 62S on line P V 68S off line data download speeds 41S 128Mb Support the number of devices Note 5 10284 10284 Note 1 Off line programming means the model can program without computer suitable for mass production On line ma...

Страница 5: ...f different models and batches may vary please refer to the actual product The power adapter is used to power the programmer during offline programming and only SP16 F SP16 FX which supports offline programming has equipped The programmer is equipped with a device adapter IC socket as standard please choose according to your needs USB Interface ZIF Socket PWR Power STA State ISP ATE Interface ...

Страница 6: ... display the programmer mode and product serial number and then you can program devices The following takes a device W25Q32BV packaged of SOIC8 208mil as an example to introduce the steps of programming devices 4 Click the toolbar button or menu Device Select Device open the Select Device dialog box select the device model to be programmed and the corresponding package W25Q32BV SOIC8 You can quick...

Страница 7: ...in the FlyPRO software for viewing Most of 8 pin devices are inserted into ZIF Socket according to the corresponding relationship on the right A very small number of devices are placed in a special way Please pay attention to the prompts that the software pops up Note ZIF Socket is only used to place the device to be programmed including IC socket It is forbidden to programming devices which have ...

Страница 8: ...d new blank device Program check Program I2C EEPROM 24 Series Program Verify Read device data and save it to file Read Verify Save Production mode After clicking Production Programming button the programmer automatically detects the placement and removal of the device and automatically completes the steps in Operational Content The software pops up a message box to remind users to pick and place d...

Страница 9: ...en Device programming completed programming successfully Red Device programming failed The above operation is only a demonstration of the conventional programming steps of the general device and the specific operation needs to be determined according to actual needs For detailed instructions on using the software please refer to the help topic of FlyPRO software ...

Страница 10: ...tatus and programming result through state lights and built in buzzer In automatic control mode connecting to automatic control machine through ISP ATE multi function interface which controls its function and outputs corresponding indication signals SP16 F supports off line manual mode only SP16 FX supports two modes above and it can be operated by any one of them through software settings Downloa...

Страница 11: ...ere is an erase item in the action content For other setting options please refer to the help topic of FlyPro software 5 Disconnect the USB cable between computer and programmer after completing off line data download and then programmer can work independently from the computer Off line operation manual mode The steps for the programmer to operate off line are as follows 1 Power the programmer wit...

Страница 12: ...ides a START enable signal and OK NG BUSY indicator ATE Interface definitions LED status for off line programming mode STA LED status Status description Manual mode Status description Automatic control mode SP16 FX only Flashing red The programmer did not download off line data The programmer did not download off line data Flashing green Waiting for device placement no status Orange Programming de...

Страница 13: ...d with FlyPRO software Click the menu Device Off line Data Management View Off line Data to open off line data viewing dialog box as shown below Offline working mode does not support ISP mode to program Use the power adapter supplied with the product when working offline Do not use other power adapters Incorrect use of other power adapters may result in damage to programmer ...

Страница 14: ...sed for programming Selecting the device mode without ISP suffix you can only program it through ZIF Socket Do not select wrong mode for both programming methods Note ISP program should use a dedicated ISP interface to connect do not connect through wires from ZIF socket ISP interface The SP16 Series Programmer provides an additional ISP interface as shown below ISP ATE interface ISP interface def...

Страница 15: ... Gray 8 Yellow 4 White 9 Green 5 Black 10 Target device connections Common 25 series and 93 24 series FLASH EEPROM connection diagrams are as follows Typical 25 series FLASH connection diagrams Typical 93 series EEPROM connection diagrams Typical 24 series EEPROM connection diagrams NOTE Different devices will have different connection methods For detailed connection information of the device plea...

Страница 16: ... to 250mA when power is supplied to the target board Overcurrent protection will occur when current exceeding this range If the target board s operating current is greater than 250mA use the target board self powered mode Target board self powered Programmer does not supply power to the target board in this mode SP16 programmer can support a target voltage range of 1 65V 5 5V The signal driving vo...

Страница 17: ...omatic programming single mass production programming download off line data SP16 F SP16 FX Support the management of project files Usage Instruction Step 1 Install multi machine application Starting in 2016 10 10 FlyPRO installation package includes SP16 series of multi machine operating software FlyPRO MCP If it has been installed Skip step 1 Download FlyPRO programmer software SP8 series SP16 s...

Страница 18: ...several minutes please wait for the installation to complete After all the drivers of programmer are installed restart the programmer If the USB hub has a power switch re switch the USB hub once Step 4 Start the FlyPRO_MCP software Click the desktop image to open the multi machine control software After startup you need to select the mode of programmer and enter on line or demo mode as needed Step...

Страница 19: ...s automatic programming mass production programming and off line data download Programmer device self test Programmer firmware upgrade Pin contact failure prompt multi machine software will directly report error and terminate the operation when pin contact is poor Test device mode View off line information in the programmer To apply the above information please use the standard stand alone softwar...

Страница 20: ...itself Programming operation steps are wrong Device working circuit voltage problem Is it possible to program devices which have already been welded on circuit board through wires from ZIF socket No The ZIF Socket is only used to place the device to be programmed including IC socket It is forbidden to operate the device soldered on the circuit board through wires from ZIF socket The peripheral cir...

Страница 21: ...data error that discovered after high temperature soldering power on operation of the product device has been read written is not in the warranty range of the programmer If you want to eliminate or verify problems with programmer it is recommended to check the device 100 before the patch is soldered For Case 1 If the device is SPI FLASH there is a way to avoid it Add protection to prevent accident...

Страница 22: ...ing software and related materials the company will try its best to solve with commercial and technical means The Company shall not be liable for any incidental consequential direct indirect special extended or punitive damages arising out of the use or sale of the product including but not limited to profits goodwill loss of availability business interruption loss of data etc shall not be liable ...

Страница 23: ...硕飞科技 SHENZHEN SOFI TECHNOLOGY www sofi tech com User Manual 23 SP16 Series programmer Appendix III Revision History Release Date Version Reviser Description 2019 06 27 B5 LiuYX First English edition ...

Отзывы: