硕飞科技
SHENZHEN SOFI TECHNOLOGY www.sofi-tech.com
User Manual
12
SP16 Series programmer
Off-line operation – automatic control mode
The automatic control mode is only applicable to SP16-FX, which is used to cooperate with automatic
equipment such as automatic programming machine and robot to realize automatic operation of devices.
When downloading off-line data, check the "Control via ISP/ATE interface" option to enable this feature. In
this mode of operation, the programmer's ATE interface provides a START enable signal, and OK / NG /
BUSY indicator.
ATE Interface definitions
LED status for off-line programming mode
STA LED status
Status description (Manual mode)
Status description(Automatic control
mode, SP16-FX only)
Flashing red
The programmer did not download
off-line data
The programmer did not download off-
line data
Flashing green
Waiting for device placement
<no status>
Orange
Programming device
Programming device
Green
Device programming completed,
programming successfully
(Waiting for device removal)
Device programming completed,
programming successfully
Red
Device programming failed
(waiting for device removal)
Device programming failed
3--BUSY 5--OK 9--NG
7--START 2
—
VCC 4/6/8/10--GND