HYD 3K~6K-EP
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
。
- 55 -
inverter. Check whether the problem is
solved.
If no, please contact technical support.
Fault
EEPROM error
ID150
FlashFault
Communication board
FLASH error
ID153
SciCommLose(D
C)
SCI
communication
error (DC)
ID154
SciCommLose(A
C)
SCI
communication
error (AC)
ID155
SciCommLose(F
use)
SCI
communication
error (Fuse)
ID156
SoftVerError
Inconsistent
software
versions
Contact for technical support and software
upgrades.
ID157
BMSCommunica
tonFault
Communication failure
of lithium battery
Make sure your battery is compatible with
the inverter.
CAN communication is recommended.
Check the communication line or port of the
battery and inverter for faults.
ID161
ForceShutdown
Force shutdown
The inverter is performed a forced
shutdown
ID162
RemoteShutdown
Remote shutdown
The inverter is performed a remote
shutdown.
ID163
Drms0Shutdown
Drms0 shutdown
The inverter is performed with a Drms0
shutdown.
ID165
RemoteDerating
Remote derating
The inverter is performed for remote load
reduction.
ID166
LogicInterfaceDe
rating
Logic interface derating
The inverter is loaded by the execution
logic interface.
ID167
AlarmAntiReflux
ing
Anti reflux derating
The inverter is implemented to prevent
countercurrent load drop.
ID177
BMS OVP
BMS
over-voltage
alarm
Internal failure of lithium battery, close
inverter and lithium battery, and wait 5
minutes to open inverter and lithium battery.
Check that the problem is resolved. If not,
please contact technical support.
ID178
BMS UVP
BMS under-voltage
alarm
ID179
BMS OTP
BMS high temperature
warning
ID180
BMS UTP
BMS low temperature
alarm
ID181
BMS OCP
Warning of overload in
charge and discharge of
BMS
ID182
BMS Short
BMS short circuit alarm
Maintenance
Inverters generally do not need any daily or routine maintenance. Heat sink
should not be blocked by dust, dirt or any other items. Before the cleaning, make
sure that the DC SWITCH is turned OFF and the circuit breaker between inverter
and electrical grid is turned OFF. Wait at least for 5 minutes before the Cleaning.
Inverter cleaning
Please clean the inverter with an air blower, a dry & soft cloth or a soft bristle
Содержание HYD 3000-EP
Страница 1: ...Shenzhen SOFARSOLAR Co Ltd Energy storage integrated inverter Product Model HYD 3K 6K EP User manual ...
Страница 13: ...HYD 3K 6K EP User manual Copyright Shenzhen SOFARSOLAR Co Ltd 8 ...
Страница 21: ...HYD 3K 6K EP User manual Copyright Shenzhen SOFARSOLAR Co Ltd 16 ...
Страница 36: ...HYD 3K 6K EP User manual Copyright Shenzhen SOFARSOLAR Co Ltd 31 Fig 4 15 Electrical connections Plan A CT ...