HYD 3K~6K-EP
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
。
- 39 -
3.Italiano
4.
......
2. Time
Set the system time for the inverter.
2.Time
OK Time
2020-05-13 17:07:00
3. Safety Param
User can modify the Safety Param of the machine through the usb flash disk,
and the user needs to copy the parameter information that needs to be modified into
the usb flash disk card in advance.
Note:To enable this feature, please contact the Sofarsolar technical support .
4. Energy Storage Mode
4.Energy Storage Mode
OK
1.Self-use Mode
OK
2.Time-of-use Mode
3.Timing Mode
4.Passive Mode
OK
Self-use Mode
In Self-use mode, inverter will automatically charge & discharge the battery.
1)
If
PV
generation
=
LOAD
consumption (ΔP < 100W) inverter
won’t charge or discharge the battery.
2)
If
PV
generation
>
LOAD
consumption, the surplus power will
be stored in the battery.
3)
If the battery is full(or already at Max
Charge Power), excess power will be
exported to the grid.
4)
If
PV
generation
<
LOAD
consumption, it will discharge the
battery to supply power to load.