Clear Produce
Clear Events
Set Country Code
(A) “Enter Setting” Interface as below:
1
.
Enter
Setting
1. Set time
2. Clear Produce
3. Clear Events
4. Set Country Code
5. Remote Control
6. Relay Command
7. Enable Set Country
Set Time
Users press “Back” button to enter “1.Enter Setting” interface, Press “OK button to enter
main setting interface. Enter “1. Set Time” by pressing“Up” button or “Down” button, then
press”OK“button and start to set up time.
Time set from year, month, day, minutes, and seconds in turns, “Up” button or “Down”button
to choose different value to set each date. Set each value is need to press “OK” button to
confirm setting. “success” is displayed if the setting time is correct, “fail” means failure
settings.
”
Users press “Back” button to enter “1.Enter Setting” interface, Press OK button to enter
main setting interface. Then Enter “2.Clear Produce” by pressing “Up” button or “Down”
button, press “OK” button and start to clear produce. “success” is displayed after settings.
“
”
Users press “Back” button to enter “1.Enter Setting” interface, Press OK button to enter
main setting interface.Enter “3. Clear Events” by pressing ”Up” button or “Down” button.
Press “OK ”button and start to clear events. “success” is displayed after settings.
“
”
Users press “Back” button to enter “1.Enter setting” interface, Press OK button to enter main
setting interface. Enter “4.Set Country Code” by pressing “Up” button Or “Down” button,
press “OK” button and enter “Input Password” Setting interface. If it's shown "set disable" on
the screen, then you can NOT choose the operating country, you should enable country
setting through "7. Enable Set Country" interface. If it's shown "set Country code?" on the
screen, then press Confirm button to start country setting. "Success" will be shown on the
screen after a successful country setting.
All rights reserved
Shenzhen SOFARSOLAR Co ., Ltd.
C
47
All rights reserved
Shenzhen SOFARSOLAR Co ., Ltd.
C
48
User manual
User manual
Operation
interface
Operation
interface
Sofar 30K~40KTL
Sofar 30K~40KTL
Document Version 1.0(2015.08.06)
Document Version 1.0(2015.08.06)
8. Set Total Energy
9. Set Mod-bus Address
10. Set Inputmode
11. Set Language
12. Set StartPara
13. Set SafetyVolt
14. Set SafetyFreq
15. Set Insulation
16. Relay Test
Code
Germany VDE
AR-N4105
Denmark
Italy CEI0-21
Australia
Spain RD1699
Turkey
Greece Continent
00
Netherland
Belgium
UK-G59
China
France
Poland
Germany BDEW
Germany VDE
0126
Italy CEI0-16
UK-G83
Greece island
EU EN50438
IEC EN61727
Korea
Sweden
Europe General
Customer
VDE
0126
30&33K
24
40K
01
02
03
04
05
06
07
08
30&33K
30&33K
30&33K
30&33K
30&33K
30&33K
30&33K
30&33K
25
26
27
28
29
30
31
32
40K
40K
40K
40K
40K
40K
40K
40K
09
30&33K
33
40K
10
11
12
13
14
15
16
17
30&33K
30&33K
30&33K
30&33K
30&33K
30&33K
30&33K
30&33K
34
35
36
37
38
39
40
41
40K
40K
40K
40K
40K
40K
40K
40K
18
30&33K
42
40K
19
20
21
22
23
30&33K
30&33K
30&33K
30&33K
30&33K
43
44
45
46
47
40K
40K
40K
40K
40K
Table 6-1 country code setting
country
country
country
Code
Code
Компания
«
Реалсолар
»,
Санкт
-
Петербург
,
Октябрьская
наб
.,
д
. 104,
к
. 1,
лит
.
П
www.realsolar.ru +7911-921-52-96