HYD 5-20KTL-3PH
User manual
Copyright ©Shenzhen SOFARSOLAR Co., Ltd
- 46 -
APP: Android: Go to Android Market and search “SolarMAN”.
IOS: Go to App Store and search “SolarMAN”.
SolarMAN-3.0-Web User Manual
,
Please visit thehttps://doc.solarmanpv.com/web/#/7.
SolarMAN-App User Manual
,
Please visit thehttps://doc.solarmanpv.com/web/#/14.
B. Communication between multiple inverters :
1. RS485
RS485 wires are connected in parallel between inverters, Connect the RS485+ and
RS485- of the inverter to the TX+ and TX- of the RS485
→
USB adapter; connect
the USB port of the adapter to the computer.
(NOTE
:
When multiple inverters are connected via RS485 wires, set
communication address to differentiate the inverters
,
please refer to this
manual<7.3.1 System setting
→
8. Communication Addr.>)
Note:
An isolated adapter must be used or the signal will be interfered.
Fig 5-19
2. WI-FI/GPRS
Refer to the figure shown below, the monitoring mode is the same as that of a
single unit.
Fig 5-20