HYD 5-20KTL-3PH
User manual
Copyright ©Shenzhen SOFARSOLAR Co., Ltd
- 33 -
Step 2
Pass the wire through the terminal, as shown in Fig.5-3
②
.
Step 3
Connect the wire to the terminal according to the identification on the
terminal, as shown in Fig.5-3
③④
.
Step 4
Connect the terminal to the machine port and rotate the clamp clockwise.
Fig.5-3 AC Load connection
A
B
A:30~50mm
B:3~5mm
①
②
③
④
⑤
⑥
5.5. AC Grid connection
Please find the correct AC Grid terminal according to the terminal accessory label.
Procedure
:
Step1
Select the appropriate cable type and specification according to the table 5-3.
The cable shall be stripped, and the specific stripping length is shown in Fig.5-4
①
.
Step 2
Pass the wire through the terminal, as shown in Fig.5-4
②
.
Step 3
Connect the wire to the terminal according to the identification on the
terminal, as shown in Fig.5-4
③④
.
Step 4
Connect the terminal to the machine port and rotate the clamp clockwise.
Fig.5-4 AC Grid connection