3.18
Figure 3.2 – BATTERY FAILURE DIAGRAM
Voltmeter
KEY : PCB : Pull–off type circuit breaker
SB : Switch–breaker
LEAVE FLIGHT IMC CONDITIONS
LAND AS SOON AS POSSIBLE
FAILING
SUCCESS
Close ”M. Switch” SB
and ”BAT” PCB
CAUTION :
Operating some equipment such as
landing gear, flaps, pump,
landing and taxi lights,
may open ALT system.
Switch off
the remaining one
LEAVE IMC CONDITIONS
LAND AS SOON AS POSSIBLE
Open ”BUS 2” – ”BUS 3” PCB
Switch off / reset :
”ALTr FLD” SB
RED OR
YELLOW
SECTOR
GREEN
SECTOR
Restore electrical
load items
one at a time
GREEN
SECTOR
RED OR YELLOW
SECTOR
Voltmeter
Set RPM
≥
2500 RPM
Check ”ALTr” PCB closed
BATTERY FAILURE
Tripping of ”Main switch” SB or ”BAT” PCB
CONTINUE