![SNR S2940-8G-v2 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/snr/s2940-8g-v2/s2940-8g-v2_configuration-manual_1310630089.webp)
SNR S2940-8G-v2 Switch Configuration Guide
DDM Configuration
(b)Configure the enable state of the transceiver monitoring
Command
Explanation
Port mode
transceiver-monitoring { enable |
disable }
Set whether the transceiver monitoring is enabled. Only the
port enables the transceiver monitoring, the system records
the abnormity state. After the port disables the function, the
abnormity information will be clear.
(c)Show the information of the transceiver monitoring
Command
Explanation
Admin mode and global mode
show
transceiver
threshold-
violation
[interface
ethernet
<interface-list>]
Show the information of the transceiver monitoring, includ-
ing the last threshold-violation informatijon, the interval of
the current transceiver monitoring and whether the port en-
ables the transceiver monitoring.
(d)Clear the information of the transceiver monitoring
Command
Explanation
Admin mode
clear
transceiver
threshold-
violation
[interface
ethernet
<interface-list>]
Clear the threshold violation of the transceiver monitor.
12.3
Examples of DDM
Example 1:
Ethernet 1/21 and Ethernet 1/23 are inserted the fiber module with DDM, Ethernet 1/24 is
inserted the fiber module without DDM, Ethernet 1/22 does not insert any fiber module, show the
DDM information of the fiber module.
a) Show the information of all interfaces which can read the real-time parameters normally, (No
fiber module is inserted or the fiber module is not supported, the information will not be shown),
for example:
Switch#show transceiver
Interface
Temp
Voltage(V)
Bias(mA)
RX Power(dBM)
TX Power(dBM)
1/21
33
3.31
6.11
-30.54(A-)
-6.01
1/23
33
5.00(W+)
6.11
-20.54(W-)
-6.02
b) Show the information of the specified interface. (N/A means no fiber module is inserted or
does not support the fiber module), for example:
Switch#show transceiver interface ethernet 1/21-22;23
Interface
Temp
Voltage(V)
Bias(mA)
RX Power(dBM)
TX Power(dBM)
1/21
33
3.31
6.11
-30.54(A-)
-6.01
89
Содержание S2940-8G-v2
Страница 11: ...SNR S2940 8G v2 Switch Configuration Guide Part I Basic Management Configuration 11...
Страница 46: ...SNR S2940 8G v2 Switch Configuration Guide Part II Port Configuration 46...
Страница 123: ...SNR S2940 8G v2 Switch Configuration Guide Part III VLAN and MAC Table Configuration 123...
Страница 164: ...SNR S2940 8G v2 Switch Configuration Guide Part IV MSTP Configuration 164...
Страница 176: ...SNR S2940 8G v2 Switch Configuration Guide Part V QoS and Flow based Redirection Configuration 176...
Страница 198: ...SNR S2940 8G v2 Switch Configuration Guide Part VI L3 Forward and ARP Configuration 198...
Страница 218: ...SNR S2940 8G v2 Switch Configuration Guide Part VII DHCP Configuration 218...
Страница 257: ...SNR S2940 8G v2 Switch Configuration Guide Part VIII Multicast Protocol 257...
Страница 278: ...SNR S2940 8G v2 Switch Configuration Guide Part IX Security Function Configuration 278...
Страница 376: ...SNR S2940 8G v2 Switch Configuration Guide Part X Reliability Configuration 376...
Страница 395: ...SNR S2940 8G v2 Switch Configuration Guide Part XI Flow Monitor Configuration 395...
Страница 403: ...SNR S2940 8G v2 Switch Configuration Guide Part XII Network Time Management Configuration 403...
Страница 411: ...SNR S2940 8G v2 Switch Configuration Guide Part XIII Debugging and Diagnosis 411...