![SNR S2940-8G-v2 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/snr/s2940-8g-v2/s2940-8g-v2_configuration-manual_1310630034.webp)
SNR S2940-8G-v2 Switch Configuration Guide
Basic Switch Configuration
Switch(config)#snmp-server
Switch(config)#snmp-server user tester UserGroup authPriv auth md5 hellotst
Switch(config)#snmp-server group UserGroup AuthPriv read max write max notify max
Switch(config)#snmp-server view max 1 include
Scenario 4:
NMS wants to receive the v3Trap messages sent by the switch.
The configuration on the switch is listed below:
Switch(config)#snmp-server enable
Switch(config)#snmp-server host 10.1.1.2 v3 authpriv tester
Switch(config)#snmp-server enable traps
Scenario 5:
The IPv6 address of the NMS is
2004:1:2:3::2
; the IPv6 address of the switch
(Agent) is
2004:1:2:3::1
. The NMS network administrative software uses SNMP protocol to obtain
data from the switch.
The configuration on the switch is listed below:
Switch(config)#snmp-server enable
Switch(config)#snmp-server community rw private
Switch(config)#snmp-server community ro public
Switch(config)#snmp-server securityip 2004:1:2:3::2
The NMS can use private as the community string to access the switch with read-write permis-
sion, or use public as the community string to access the switch with read-only permission.
Scenario 6:
NMS will receive Trap messages from the switch (Note: NMS may have commu-
nity string verification for the Trap messages. In this scenario, the NMS uses a Trap verification
community string of usertrap).
The configuration on the switch is listed below:
Switch(config)#snmp-server host 2004:1:2:3::2 v1 usertrap
Switch(config)#snmp-server enable traps
2.4.6
SNMP Troubleshooting
When users configure the SNMP, the SNMP server may fail to run properly due to physical con-
nection failure and wrong configuration, etc. Users can troubleshoot the problems by following the
guide below:
• Good condition of the physical connection.
• Interface and datalink layer protocol is Up (use the
'show interface'
command), and the
connection between the switch and host can be verified by ping (use
'ping'
command).
• The switch enabled SNMP Agent server function (use
'snmp-server'
command)
• Secure IP for NMS (use
'snmp-server securityip'
command) and community string (use
'snmp-server community'
command) are correctly configured, as any of them fails, SNMP
will not be able to communicate with NMS properly.
34
Содержание S2940-8G-v2
Страница 11: ...SNR S2940 8G v2 Switch Configuration Guide Part I Basic Management Configuration 11...
Страница 46: ...SNR S2940 8G v2 Switch Configuration Guide Part II Port Configuration 46...
Страница 123: ...SNR S2940 8G v2 Switch Configuration Guide Part III VLAN and MAC Table Configuration 123...
Страница 164: ...SNR S2940 8G v2 Switch Configuration Guide Part IV MSTP Configuration 164...
Страница 176: ...SNR S2940 8G v2 Switch Configuration Guide Part V QoS and Flow based Redirection Configuration 176...
Страница 198: ...SNR S2940 8G v2 Switch Configuration Guide Part VI L3 Forward and ARP Configuration 198...
Страница 218: ...SNR S2940 8G v2 Switch Configuration Guide Part VII DHCP Configuration 218...
Страница 257: ...SNR S2940 8G v2 Switch Configuration Guide Part VIII Multicast Protocol 257...
Страница 278: ...SNR S2940 8G v2 Switch Configuration Guide Part IX Security Function Configuration 278...
Страница 376: ...SNR S2940 8G v2 Switch Configuration Guide Part X Reliability Configuration 376...
Страница 395: ...SNR S2940 8G v2 Switch Configuration Guide Part XI Flow Monitor Configuration 395...
Страница 403: ...SNR S2940 8G v2 Switch Configuration Guide Part XII Network Time Management Configuration 403...
Страница 411: ...SNR S2940 8G v2 Switch Configuration Guide Part XIII Debugging and Diagnosis 411...