![SnowEx HELIXX Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/snowex/helixx/helixx_owners-manual_1309794023.webp)
Lit. No. 31022EN, Rev. 00
23
June 1, 2022
OPERATING THE SPREADER – CAB CONTROL
ON Mode
Vehicle ignition is set to ACC or ON; cab control is ON.
Spinner and hopper motors will start. All cab control
functions are operational. Accessory lights and
vibrator (if installed) are operational.
During normal spreader operation,
no control codes
are displayed
. Information or setup codes will appear
when relevant. These codes will not stop spreader
operation.
Error Mode
When an error condition occurs, spreader operation
will shut down. A two-character error code will flash
on the display and a beep will sound. If there are
multiple error codes, the codes will flash in a repeating
sequence.
Refer to the Error Codes portion of the
following Cab Control Codes table. Also see the
Troubleshooting Guide section of this manual.
Once the error condition has been resolved, press the
ON/OFF button to clear the error code(s). Press the
ON/OFF button again to resume spreader operation.
The error code will reappear if the error condition
has not been rectified. If the error condition persists,
contact your authorized dealer.
Multiple resets within a short time frame will cause
the hopper module to time out if components are
overheating. The control will display an
EF
error code.
Accessory work lights and strobe lights can be used
when an error code is in effect and will remain in their
current state. The vibrator and pre-wet, if installed, will
not function.
Содержание HELIXX
Страница 2: ......
Страница 35: ...Lit No 31022EN Rev 00 35 June 1 2022 This page intentionally left blank...