Installation
Issue 1 Rev 12
Page 11
© 2013 Snell Limited
2.
Installation
The MV-16 1U frame may be installed in 19 inch bays with 426mm depth (~450mm including
connectors). Ventilation is produced in each frame with exhaust fans on the left hand side
(viewed from front) and intake grilles at the right. Frames should be installed into bays such
that airflow through these apertures is not impeded.
The front rack ears are intended to provide a means of retaining the unit in the rack.
2.1 Power and fuses
The mains voltage (240/100 Volts) will be auto detected provided it is in the range
90 - 264 V AC and 50/60 Hz. A 5 A fuse is fitted and a spare fuse should be located under the
pull-out flap.
The IEC power inlet is the mains disconnection device for this unit.
2.2 Health and safety considerations
The Installation and Maintenance of the MV-16 unit and any associated equipment must be
carried out by PERSONS SUITABLY QUALIFIED to work with equipment which may be
connected to the mains supply.
The unit MUST BE DISCONNECTED & ISOLATED FROM THE MAINS INPUT and from
other product outputs before undertaking maintenance.
ELECTRIC SHOCK HAZARDS exist if conductive instruments, neck chains or fingers etc. are
placed within the unit or in close proximity of the input/output terminals/connectors.
Incorrect installation can cause internal components to rupture and particles to be ejected
from the product.
TOXIC FUME HAZARDS exist if the unit is subjected to direct flames or excessive
temperature of above 100 Degrees Centigrade ambient.
The mounting and installation of the unit must be arranged by the user to comply with all
safety regulations by the indigenous authority.
2.2.1 Disposal
Do not incinerate as explosive and toxic fume hazards exist. Disposal must be by dismantling
the product to component level and disposing of each component by an approved method.
Fig 4.
The 1U MV-16 frame showing main side to side ventilation.
Important:
To ensure adequate support the unit MUST also be supported at the rear of the frame.
Please ensure that ventilation is not impaired when selecting suitable supports.
For your own protection, observe the following safety precautions when installing,
operating and servicing your device:
Содержание MV-16
Страница 2: ...MV 16 Multiviewer www snellgroup com Issue 1 Rev 12 Page 2 2013 Snell Limited...
Страница 6: ...MV 16 Multiviewer www snellgroup com Information and Notices Issue 1 Rev 12 Page 6 2013 Snell Limited...
Страница 16: ...MV 16 Multiviewer www snellgroup com Installation Issue 1 Rev 12 Page 16 2013 Snell Limited...
Страница 56: ...MV 16 Multiviewer www snellgroup com Operation Issue 1 Rev 12 Page 56 2013 Snell Limited...
Страница 86: ...MV 16 Multiviewer www snellgroup com Hydra Open Protocol Issue 1 Rev 12 Page 86 2013 Snell Limited...
Страница 90: ...MV 16 Multiviewer www snellgroup com Technical Appendix Issue 1 Rev 12 Page 90 2013 Snell Limited...