background image

Version 1 Issue 1

www.snellgroup.com

IQOTR30

Page 7

Warnings

All lasers used in this product are Class 1, in accordance with EN60825-1 as 
well as 21CFR 1040.10 and 1040.11

Laser light can be damaging to the eyes. Optical fibers and uniters should be 
handled with great care.

The IQOTR30 is designed for use with Class 1 laser systems only. Ensure 
that all outputs do 

not

 exceed Class 1 as doing so will impair the safety of the 

system and may result in damage to the equipment.

Active fibers should not be handled unless thier source can positively be 
identified as not exceeding Class 1 limits.

Notes

Note: 

Optical uniters have shutters to prevent the ingress of dust. These shutters 
should only be opened when connecting optical fibers.

The ends of optical fibers should be cleaned with a liquid fiber cleaner, using 
a cotton bud, to ensure that there is no dust present before they are plugged 
in (the uniter is polarized).

Do not disturb or handle the optical fibers.

Содержание IQOTR30

Страница 1: ...House Eastleigh Road Havant Hants PO9 2PE United Kingdom For General Enquiry s contact Tel 44 0 2392 489000 Fax 44 0 23 9245 1411 For Technical assistance contact Tel 44 0 2392 489058 Fax 44 0 2392 489057 Web http www snellwilcox com support Ftp ftp ftp snellwilcox com support May 2009 Operator s Manual ...

Страница 2: ...ary 3 Technical Profile 4 Warnings 7 Notes 7 Connections 8 IQOTR30 Connections 8 Card Edge Controls 9 IQOTR30 9 Controlling the IQOTR30 from the RollCall Control Panel 10 Unit Status 10 Input 11 Memory 1 16 13 Logging 14 RollTrack 17 Setup 19 Operation from an Active Control Panel 21 Information Window 21 Control Window 21 Manual Revision Record 22 ...

Страница 3: ... signals to 1310 nm wavelength optical signals Network control monitoring intelligence and Built in Intelligence SDI TX 1 1 2 SDI RX Signal Equalisation Fiber Optic Transmitter CH 1 Fiber Laser Status Monitor Inputs Outputs SDI TX CH 2 Fiber Fiber RX Input Light Detect Monitor 2 1 Re clocker Rate Detection Re clock Bypass Re clocker Rate Detection Re clock Bypass ...

Страница 4: ...r Panel View TX OUT SDI OUT 1 IQOTR30 33 1A 2 1 SDI IN RX SDI OUT 2 1 RX IN These modules can only be fitted into A style enclosures as shown below Enclosure order codes IQH3A S 0 IQH3A S P Enclosure order codes IQH3A E 0 IQH3A E P IQH3A 0 0 IQH3A 0 P Enclosure order code IQH1A S P ...

Страница 5: ...ngle mode fiber optic receiver for 3G HD SD SDI and DVB ASI Signals Input wavelength range 1260 1620 nm 3G HD SD SDI outputs for CH 2 optical input in accordance with SMPTE424M SMPTE292M SMPTE259M and DVB ASI IQOTR30 IQOTR3033 1A Single mode fiber optic transceiver for HD SD SDI 1 x HD SD SDI input 2 x HD SD SDI outputs 1 x optical output 1 x optical input 2 x HD SD SDI outputs IQOTR3033 1A3 Singl...

Страница 6: ...lemode panel uniter Standard SMPTE 297 2006 Input 1 Signal Outputs Tx Optical 3 GBit s HD SDI 1 485 Gbit s HD SDI or 270 Mbit s SD SDI asynchronous operation available at other frequencies Connector Format SC PC singlemode panel uniter Outputs 1 per channel Conforms to SMPTE 297 2006 Electrical 3 GBit s HD SDI 1 485Gbit s HD SDI or 270 Mbit s SD SDI asynchronous operation available at other freque...

Страница 7: ...te Input 1 2 Present Input 1 2 Error Input 1 2 Loss Tx Laser Bias High Warning Tx Power Low Warning Tx Power High Warning Tx Laser Wavelength Rx Power High Warning Rx Power Low Warning Rx Power Measurement RollTrack Controls On Off Index Source Address Command Status Sending RollTrack Outputs Unused Input 1 2 Present Input 1 2 Rate Unknown Input 1 2 Loss Input 1 2 3G Input 1 2 HD Input 1 2 SD Tx L...

Страница 8: ... width FWHM 1 5 nm typ Output power 2 dBm 1 dBm Extinction ratio 7 5 1 typ Transmission distance Up to 30 Km Optical Inputs Rx Input wavelength range Min 1260 nm Max 1620 nm Optical power input range 3 dBm 18 dBm Detector damage threshold 3 5 dBm Module Power Consumption 3 5W max ...

Страница 9: ...ss 1 as doing so will impair the safety of the system and may result in damage to the equipment Active fibers should not be handled unless thier source can positively be identified as not exceeding Class 1 limits Notes Note Optical uniters have shutters to prevent the ingress of dust These shutters should only be opened when connecting optical fibers The ends of optical fibers should be cleaned wi...

Страница 10: ...connector Electrical Outputs SDI OUT 1 There are two serial digital outputs via BNC 75 ohm panel jack connectors The input source for these outputs is the SDI IN connector Electrical Outputs RX SDI OUT There are two serial digital outputs via BNC 75 ohm panel jack connectors The input source for these outputs is the RX IN connector TX OUT SDI OUT 1 IQOTR30 33 1A 2 1 SDI IN RX SDI OUT 2 1 RX IN TX ...

Страница 11: ...Version 1 Issue 1 www snellgroup com IQOTR30 Page 9 Card Edge Controls IQOTR30 OK WARNING ERROR POWER OK CPU OK OK WARNING ERROR CH1 CH2 ...

Страница 12: ...Information about the status of the unit is displayed in the Unit Status section on each RollCall Control Panel screen The first two lines of the Unit Status display the input status detected rate and input selection method for Input 1 The third and fourth lines of the Unit Status display the same information for Input 2 ...

Страница 13: ...is selected the output will be passed through SD DVB ASI 270 Mb When selected the unit will reclock only SD DVB ASI 270 Mb signals When selected the On Input Loss controls are greyed out and are inactive If any other standard is applied to the unit the output will be muted HD 1 5 Gb When selected the unit will reclock only HD 1 5 Gb signals When selected the On Input Loss controls are greyed out a...

Страница 14: ...Tx 1 This section displays the following information about the fiber optic output signal Tx Wavelength Laser Bias Laser Bias State Tx Power Tx Power State Laser OFF Selecting this option disables the laser Laser OFF On Input Loss Selecting this option disables the laser if the input signal is lost Fiber Optic Rx 2 This section displays the following information about the fiber optic input signal R...

Страница 15: ...e Memory Name field type the new memory name and then cli click S To return the memory to its default value click the preset button P Use the Recall Memory function to recall the settings saved in a memory location Last Recalled Memory displays the most recently recalled memory An asterisk next to the name displayed in the Last Recalled Memory field indicates that one or more controls has been cha...

Страница 16: ...Version 1 Issue 1 www snellgroup com IQOTR30 Page 14 Logging Information about several parameters can be made available to a logging device that is connected to the RollCall network ...

Страница 17: ...eld Log Value Displays the current log value RollCall Log Fields Log Field Log Value SN Serial number OS_VERSION Operating system version BUILD_NUMBER Software build number HARDWARE_VERSION Hardware version number UPTIME Time since last restart LICENSED_OPTIONS Currently licensed options INPUT_N_IDENT Input ident INPUT_N_NAME Input name INPUT_N_TYPE Input type INPUT_N_STATE OK WARN FAIL INPUT_N_SD...

Страница 18: ...QOTR30 Page 16 OUTPUT_1_LASER_BIAS Current Laser Bias in mA OUTPUT_1_TX_POWER_STATE OK WARN FAIL OUTPUT_1_TX_POWER Tx Power in dbm OUTPUT_1_WAVELNGTH Wavelegth in nm INPUT_N_ RX_POWER_STATE OK WARN FAIL INPUT_N_RX_POWER Rx power measurement ...

Страница 19: ...e example is the network segment code number The second set 10 in the example identifies the enclosure mainframe unit The third set 01 in the example identifies the slot number in the unit The fourth set 99 in the example is the RollCall ID of the destination unit a user configured number that uniquely identifies the destination unit in a multi unit system If it is set to anything other than 00 th...

Страница 20: ... RollTrack Information RollTrack Sending and RollTrack Status display information about the status of RollTracks RollTrack Sending displays the information when the unit is actively sending a RollTrack command No The command is not being sent Yes The command is being sent RollTrack Status displays the status of the currently selected RollTrack Index OK RollTrack message sent and received OK Unknow...

Страница 21: ...splays the unit s serial number Build This displays the factory build number This number identifies all parameters of the unit KOS This displays the operating system version number PCB This displays the PCB revision number Licensed Options This displays the unit s currently licensed options To reboot the unit simulating a power up power down cycle click Restart To reset all of the unit s settings ...

Страница 22: ...p com IQOTR30 Page 20 Input 1 Name and Input 2 Name These are the input names displayed in logging To change the name of Input 1 or Input 2 type the name in the text field and click S To return the name to its factory default click P ...

Страница 23: ...it Control Window The Control window displays all selection menus and sub menus The main or top level menu allows various sub menus to be selected by pressing the button adjacent to the required text line Note that where a menu item is followed by three dots this indicates that a further sub menu may be selected Whenever a menu item is selected the parameters of that selection will be displayed in...

Страница 24: ...Version 1 Issue 1 www snellgroup com IQOTR30 22 Manual Revision Record Date Version Issue Change Comments 12 05 09 1 1 First Issue ...

Отзывы: