HD5050
SECTION 3
HD5050070999 Version 1 Issue 4
For Software Version Z5 onwards
3.5
GPI
GPI Inputs are accessed via a 25 way male D-type
connector labelled GPI Input.
,1387
GPI input
Contact pins
Action
1
12, 25
Recall Machine Memory 1
2
11, 24
Recall Machine Memory 2
3
10, 23
Recall Machine Memory 3
4
9, 22
Recall Machine Memory 4
5
8, 21
Recall Display Preset Full Height
6
7, 20
Recall Display Preset Full Width
7
6, 19
Recall Display Preset Insert
8
5, 18
Recall Display Preset Anamorphic
9
4, 17
Recall Display User Memory 1
10
3, 16
Recall Display User Memory 2
11
2, 15
Recall Display User Memory 3
12
1, 14
Recall Display User Memory 4
13
Ground
GPI outputs are accessed via a 25-way female
D-type connector and connections are as follows:
287387
GPI output
Contact pins
Action
1
2, 14
Machine Memory 1 Selected
2
3, 15
Machine Memory 2 Selected
3
4, 16
Machine Memory 3 Selected
4
5, 17
Machine Memory 4 Selected
5
6, 18
Display Preset Full Height Selected
6
7, 19
Display Preset Full Width Selected
7
8, 20
Display Preset Insert Selected
8
9, 21
Display Preset Anamorphic Selected
9
10, 22
Display User Memory 1 Selected
10
11, 23
Display User Memory 2 Selected
11
12, 24
Display User Memory 3 Selected
12
13, 25
Display User Memory 4 Selected
1
Ground
Output Polarity
The GPI outputs can be set to either ON or
INVERT.
If ON is selected the contact action will be from
open to closed.
If INVERT is selected the contact action is from
closed to open.