IQSDA41/42
Operation Using the RollCall Control Panel
Issue 1 Rev 1
Page 24
© 2017 SAM
5.8 RollTrack
The
RollTrack
page allows information to be sent, via the RollCall network, to other
compatible units connected on the same network.
5.8.1 Disable All
When checked, all RollTrack items are disabled.
5.8.2 Index
This slider enables up to 16 RollTrack outputs to be set up. Dragging the slider selects the
RollTrack Index number, displayed below the slider. Clicking the
P
button selects the default
preset value.
5.8.3 Source
This enables selection of the source of information which is to trigger the transmission of data.
Clicking the
P
button selects the default preset value. When no source is selected,
Unused
is
displayed.
RollTrack Source
Description
User Memory 1-16
User-defined.
Unused
No RollTracks sent.
Input N OK
Input N is good.
Input N LOST
Input N is bad.
Input N Bitrate 12G
Received bit rate is 12 Gbit/s.
Input N Bitrate 6G
Received bit rate is 6 Gbit/s.
Input N Bitrate 3G
Received bit rate is 3 Gbit/s.
Input N Bitrate 1.5
Received bit rate is 1.5 Gbit/s.
Input N Bitrate 270
Received bit rate is 270 Mbit/s.
Input N Bitrate Un.
Received bit rate is unknown.
TX N Bias OK
LASER Bias currently within limits.