IQSDA41/42

Operation Using the RollCall Control Panel

Issue 1 Rev 1

Page 26

© 2017 SAM

RollTrack Source

Description

OK

RollTrack message was sent and received successfully.

Unknown

RollTrack message has been sent but transmission has not 
yet completed.

Timeout

RollTrack message has been sent but no acknowledgement 
received. This could be because the destination unit is not at 
the location specified.

Bad

RollTrack message has not been correctly acknowledged at 
the destination unit. This could be because the destination 
unit is not of the type specified.

Disabled

RollTrack sending is disabled.

Содержание IQSDA41

Страница 1: ...s a m com User Manual IQSDA41 Single Dual Channel 12G 3G HD SD SDI Re clocking Distribution Amplifier with RollCall IQSDA42 Multi Channel 12G 3G HD SD SDI Re clocking Distribution Amplifier with RollC...

Страница 2: ...r authorized agents Reproduction or disassembly of embedded computer programs or algorithms prohibited No part of this publication can be transmitted or reproduced in any form or by any means electron...

Страница 3: ...al L Phase N Nulleiter N Nulleiter L Phase E Schutzleiter E Schutzleiter Explicaci n de los S mbolos de Seguridad ste s mbolo refiere al usuario informaci n importante contenida en la literatura inclu...

Страница 4: ...INGEN BRUGER SERVICERBARE DELE SERVICE M KUN UDF RES AF FAGL RTE PERSONER F 0 J 0 F J Han stik Hun stik F rklaring av S kerhetssymboler Denna symbol h nvisar anv ndaren till viktig information som ter...

Страница 5: ...menos que seja efectuadas por t cnicos habilitados Para reduzir o risco de choque el ctrico n o expor este equipamento chuva ou humidade Assegurar que a unidade est sempre devidamente ligada terra e...

Страница 6: ...rformance of Cables and Connectors SAM products are designed to meet or exceed the requirements of the appropriate European EMC standards In order to achieve this performance in real installations it...

Страница 7: ...n the RollCall Template 16 5 1 1 Setting Values 16 5 1 2 Template Pages 16 5 2 Information Window 17 5 3 Input Output Page 18 5 3 1 Configuration 18 5 3 2 Inputs 18 5 3 3 Outputs 18 5 4 Setup 19 5 4 1...

Страница 8: ...tion applications 1 1 1 1 Block Diagram 1 1 1 2 Feature Summary The IQSDA41 provides the following features Intelligent UHD 1 12 Gbit s HD 3 Gbit s or 1 5 Gbit s and SD SDI re clocking distribution am...

Страница 9: ...lization performance coupled with excellent packing density make it ideal for signal dense distribution applications 1 1 2 1 Block Diagram 1 1 2 2 Feature Summary The IQSDA42 provides the following fe...

Страница 10: ...ier 1 input 7 outputs or 2 inputs 3 outputs per input 2 optical inputs or 2 optical outputs IQSDA4101 1B4 12G 3G HD SD SDI Re clocking Distribution Amplifier 1 input 9 outputs or 2 inputs 4 outputs pe...

Страница 11: ...Rx 1 x 12G Tx 1310nm FC1 13T2 12G Fiber transceiver 2 x 12G Tx 1310nm FC1 13R2 12G Fiber transceiver 2 x 12G Rx Important Although IQ modules are interchangeable between enclosures their rear panels...

Страница 12: ...level A B SMPTE 292M HD SMPTE 259M C SD Control Interface Electrical TTL compatible active low driven Connector Format HD BNC 75 Ohm panel jack on standard SAM connector panel Controls Indicators Powe...

Страница 13: ...memories Default Settings Resets all module settings to factory specified default values but does not clear memories Restart Software restart of the module Module Information Reports the following mo...

Страница 14: ...the gray shading and the twin ID numbers the number in white is the input number and the number in black is the output number 3 1 SDI Input Output Serial digital inputs and outputs are via HD BNC con...

Страница 15: ...s on the rear panel of the module indicate input status There is one LED per input When Green Input enabled signal valid When Yellow Input disabled or Reclocker Bypass active When Red No signal on inp...

Страница 16: ...within the templates have values either alpha or numeric When setting a value in a field the value whether text or a number must be saved by pressing the ENTER key or clicking the Save Value button Cl...

Страница 17: ...Issue 1 Rev 1 Page 17 2017 SAM 5 2 Information Window The Information window is displayed at the top of each page next to the pages list It can displays basic information about the input and output s...

Страница 18: ...n the option selected 5 3 2 Inputs These controls are used to configure inputs select the input rate s to be re clocked Re clocking can be disabled on an output by output basis if required see section...

Страница 19: ...odule serial number Build Factory build number This number identifies all parameters of the module OS Operating system version number PCB Printed Circuit Board revision number PCB Mods PCB modificatio...

Страница 20: ...Control Panel Issue 1 Rev 1 Page 20 2017 SAM 5 4 4 Input Name These are the input names displayed in logs To change the name of Input 1 or Input 2 type the name in the text field and click S To return...

Страница 21: ...me and version BUILD_NUMBER Reports the build number HARDWARE_VERSION Reports the hardware version number HARDWARE_MOD Reports the hardware modification number ROL_STATES Reports the RollCall status V...

Страница 22: ...is the input number Log Field Description INPUT_N_STATE Reports current state of the input signal Valid values are OK input signal good FAIL input signal not detected INPUT_N_SDIRATE Reports current...

Страница 23: ...te log fields as required Where N is the input number Log Field Description OUTPUT_N_STATE Valid values are OK output signal good FAIL output signal not detected WARN Freeze WARN Pattern WARN Black OU...

Страница 24: ...5 8 3 Source This enables selection of the source of information which is to trigger the transmission of data Clicking the P button selects the default preset value When no source is selected Unused...

Страница 25: ...t The command may be changed by typing a code in the text area and then selecting the S button to save the selection Clicking the P button returns to the default preset command The RollTrack command c...

Страница 26: ...has been sent but transmission has not yet completed Timeout RollTrack message has been sent but no acknowledgement received This could be because the destination unit is not at the location specifie...

Страница 27: ...on it The recalled settings will be applied and the memory name will appear in the Last Recalled Memory section 5 9 2 Save Memory This column lists the 16 pre set memory names that are available for u...

Страница 28: ...ings have been changed since it was recalled an asterisk will be displayed after the memory name 5 9 4 Save Memory Name This option enables the pre set memory names to be changed to something more mem...

Отзывы: