Scope Multimeter
Optional Settings
120
12.7.2 Divisions
The Divisions options allow you to change (to your preference) how the Vertical
Scale Menu selections are represented, and the type of value that displays in the
Vertical Scale icon.
This section describes the following settings:
•
Trace
–
Trace Full Scale
–
Trace Per Division
•
Display
–
Display Full Scale
–
Display Per Division
The following illustration is for reference, and identifies key terms and features used
in this manual.
1— Vertical Scale
2— Sweep (horizontal or time) Scale
3— Vertical Scale Menu
4— Vertical Scale Icon
Figure 12-28
z
To access the divisions option menu:
1.
Select
Tools
from the Home screen.
2.
Select
Settings
from the Tools and Setup menu.
3.
Select
Configure Scope/Meter
from the Settings menu.
4.
Select
Divisions
from the menu.
5.
Select either option:
–
Trace Settings
- see
–
Display Settings -
see
6.
Select the
Back
icon or press the
N/X
button to return to the Settings menu.
Trace Settings
The Trace Settings option allows you to change how the vertical scale menu
selections are represented.
NOTE
This setting ONLY changes the vertical scale, the sweep (horizontal) scale is
NOT changed.
NOTE
When adjusting the vertical scale setting, it is important to remember that the
vertical scale is divided into 10 major divisions, and all scale adjustments
reflect this factor of 10. The division set of 10 cannot be changed, divisions
cannot be added or removed.
1
2
3
4