Figure 14 – Air Control Valve and Air lines
3. Connect Air Hoses and Run Testing
- Uncoil the polytubes under each runway that is connected to the safety lock release air cylinder
shown on
Figure 15
. Route these two lines from base frames to the union ‘Y’ connector in the
console. See
Figure 14
.
- Uncoil the polytube that one end is connected to the Terminal bolt for Jackbeam on the driver
side runway, shown on
Figure 15
. Connect other end to the Swivel Tee in the console, See
Figure 14
.
IMPORTANT: Use one 1/4" NPT cap to plug terminal bolt before connect to air supply.
- Mount a 1/4” NPT fitting (
not supplied)
to the inlet port at FRL unit. Connect the shop air supply
line to this fitting.
IMPORTANT: Shop air must be connected to the inlet port at the FRL unit
on the console, in order for lift to operate.
- Remove the black hex socket cap on the top of Lubricator, Fill the Lubricator Reservoir with
Snap-On Air Motor Oil #IM6 or Equivalent up to 4/5 of oil reservoir height, re-install the cap.
How to fill oil and adjustment reference to
Section 12.3.
- After connecting the main air line, check the air system for any leaks.
Note: The console is equipped with an air Filter/Regulator/Lubricator to ensure a clean air
supply is provided to the safety release cylinders, Jackbeams, The Air Regulator should
be set between 0.62 - 0.83Mpa (90-120psi).
Содержание EELR501A
Страница 6: ...6 of 73 2 0 SAFETY WARNING DECALS...
Страница 8: ...8 of 73 Figure 2 Lift Dimensions Side View Figure 3 Lift Dimensions Back View...
Страница 18: ...18 of 73 Figure 12 Hydraulic Connections...
Страница 33: ...33 of 73 Figure 31 Connection of Air Recoil Hose...
Страница 61: ...61 of 73 16 0 HYDRAULIC AND AIR LINE ASSEMBLY 16 1 Hydraulic Line Routing Map Figure 51 Hydraulic Items Map...
Страница 64: ...64 of 73 16 6 Air Line Routing Map Figure 53 Air Hose Assembly...
Страница 69: ...69 of 73 17 5 Console Labeling Figure 57 Console Labeling...
Страница 74: ...74 of 73 APPENDIX Foundation Plan...