SMT SMT-1100W Скачать руководство пользователя страница 9

User Operated Controls

 

 ON/OFF  Switch:

 The Power ON/OFF switch is used to turn the pump motor on and off as necessary for operation. The ON/OFF switch 

is located on the upper right corner of the SMT-600-W cover. The SMT-1100-W ON/OFF switch is located just under the cover on the 

left side of the unit.

 

 Gun:

 The spray gun assembly provides operator control of the flow, pressure and pattern of the high-pressure spray. The spray gun 

is connected to the output end of the high-pressure hose by quick-connect fittings. Squeezing the gun trigger while directing the 

spray nozzle toward the surface or equipment to be cleaned operates the spray gun. Your spray gun may be equipped with a dual 

nozzle or a vari-nozzle.

 

 Dual  Nozzle: 

The dual nozzle selector is used 

to select either the low-pressure "soap" nozzle 

or the high-pressure "rinse" nozzle. Selection of 

the desired nozzle must be made while the spray 

gun trigger is released. To select the low-pressure 

nozzle, rotate the spray gun 90° counter-clockwise 

so that the spray gun handle is parallel to the 

ground with the hose connection extending to 

the operators right, then squeeze the trigger. To 

select the high-pressure nozzle, rotate the spray 

gun 90° clockwise so that the spray gun handle 

is parallel to the ground with the hose extending 

to the operator’s left, then squeeze the spray 

gun trigger. Once the nozzle has been selected 

and the spray gun trigger held open, the spray 

gun may be rotated and aimed in any direction 

without affecting pressure nozzle selection.

 

 Vari-Nozzle:

 The vari-nozzle is used to select 

either low-pressure "soap" or high-pressure 

"rinse", and to adjust the spray-pattern from a 

wide-angle spray to a zero degree stream. Moving 

the black body of the nozzle toward or away from 

the gun handle respectively makes selection of 

high or low pressure. For high-pressure, pull the 

black nozzle-body firmly toward the spray-gun 

handle. To select low-pressure, push the black 

nozzle-body firmly away from the spray-gun 

handle. To vary the spray-pattern of the nozzle, 

twist the black nozzle-body for the desired spray-

pattern.

 

 Chemical Metering Selectors (600 series):

 This 

control allows the operator to select a chemical 

to be injected and meter it into the low-pressure 

spray. It also provides a means to flush the 

chemical injector after each use. The Chemical 

Metering Selector is located on the lower left front corner of the SMT-600-W cover. This control is optional on the SMT-1100-W and 

is located on the upper right corner of the cover when so equipped. Turning the selector knob from the "OFF" position counter-

clockwise selects and meters the chemical. The farther the control knob is turned, the higher the chemical concentration out the 

spray gun. See the chemical dilution chart and instructions on the back page of this manual. To flush the chemical injector, turn the 

metering knob fully clockwise and operate the spray gun and pump on low pressure for one minute.

 

 Chemical Metering Knob (SMT-1100-W): 

The Chemical Metering Knob is located on the chemical injector and is used to set the 

chemical concentration in the spray output. The chemical metering knob has a graduated scale that is used for reference setting 

only. Turn the metering knob fully clockwise for NO chemical. Turn the metering knob counter-clockwise to increase the chemical 

concentration to the desired strength. See the chemical dilution chart on the back page of this manual.

Operation

9

Содержание SMT-1100W

Страница 1: ...rvice problem or need help please call our toll free number 1 800 548 3373 or 479 636 5776 TERMS All parts will be shipped with check in advance or C O D Commercial accounts are allowed 15 day terms f...

Страница 2: ...ard or recaptured water excessive hot water temperatures exceeding 120 Fahrenheit 49 Celsius using bleach as an injected chemical or using hydrogen peroxide as an injected chemical www spraymastertech...

Страница 3: ...resolved then please call our toll free customer service number 1 800 548 3373 or 479 636 5776 Service Requirements Water Flow minimum 5 GPM at 30 PSI Temperature 40 to 120 F maximum 125 F Electric SM...

Страница 4: ...alcohol or drugs Keep operating area clear of all persons Do not overreach or stand on unstable support Keep good footing and balance at all times Follow the maintenance instructions specified in the...

Страница 5: ...considerations will help to ensure the unit is properly installed in the best location with minimal difficulty Location Safety and convenience during use and servicing of the equipment should be a pri...

Страница 6: ...upply to the unit must have a flow rate of at least 5 GPM at a pressure of 30 PSI Anything less may cause intermittent shutdown of the system Water temperature Water supply temperatures in excess of 1...

Страница 7: ...rections in the instruction sheet provided with the hardware kit Loosely install the nuts on the shock mounts on the underside of the brackets These will be wrench tightened after the pump is secured...

Страница 8: ...onnected to the water supply bibb and the hose bibb valve is fully open Circuit Breaker main Set the circuit breaker in the main panel to the on position GFCI Connect the unit GFCI power cord to the d...

Страница 9: ...d to adjust the spray pattern from a wide angle spray to a zero degree stream Moving the black body of the nozzle toward or away from the gun handle respectively makes selection of high or low pressur...

Страница 10: ...y gun firmly Direct the spray gun nozzle away from individuals DANGER Electrocution Serious injury or death Do not spray energized electrical equipment or electrical outlets Set ON OFF switch to ON Di...

Страница 11: ...versely affect operation Pour 8 ounces of de liming agent into the full float tank With the spray gun connected and closed turn the pump ON and allow recirculation for 5 minutes After recirculation di...

Страница 12: ...to achieve the manufacturer s recommended chemical solution strength Example a 2 9 gallon per minute GPM pump used to apply a chemical requiring a mix ratio of 4 ounces per gallon will need to inject...

Отзывы: