SMT SMT-1100W Скачать руководство пользователя страница 7

Installation Procedure  (continued)
  

Refer to Figure 3 and Figure 4 for installation of the SMT-1100W.  The SMT-1100W installation is similar to the installation of the  

SMT-600W. Differences in the installation are easily recognizable and should present little difficulty in adapting the instructions for 

the SMT-600W to the installation of the SMT-1100W.

Brackets, Hose Reel & Hose 

Installation

   

Wall-mount brackets and 

hose reel 

- Brackets must be 

installed on 16-inch centers 

to align with the mounting 

holes in the frame of the 

pump and hose reel. Locate 

the mounting-holes for the 

brackets on the wall using 

the template provided as 

part of the shipping carton. 

Install the two wall-mount 

brackets with appropriate 

hardware. If a wall-mount 

hose reel is to be installed 

with the pump unit it will 

be attached with the same 

hardware that attaches the 

lower part of the wall-mount 

brackets. Attach the brackets 

to the wall with the top hole 

in the bracket, and then 

attach the hose reel to the 

lower part of the brackets. 

Install the hose reel and brackets together. 

 

 High-pressure  hose

 - Install the high-pressure hose on the hose reel by inserting the threaded end of the hose through the hole in 

the flange of the reel and tighten into the fitting on the handle side of the reel. Wrap the threads of the fitting with several wraps of 

Teflon tape. Secure the hose to the reel flange with the two rubber-coated clamps on the reel.

Main Pump Installation

 

 Vibration/shock-mount

: Install four shock-mount pads onto the wall mount brackets following the directions in the instruction 

sheet provided with the hardware kit. Loosely install the nuts on the shock-mounts on the underside of the brackets. These will be 

wrench tightened after the pump is secured to the brackets.

 

 Pump

: Remove the stainless steel cover from the pump.

 

 

•   Place two 2-by-4’s across the two previously installed wall-mount brackets between and contacting the shock-mounts. Place 

the pump on the 2-by-4’s, centered over the wall-mount brackets, with the blue tank to the left rear. Position the pump frame 

to align the holes in the bottom of the frame with the shock-mounts. Screw the shock-mounts up into the frame 1/2 turn past 

contact between the frame and the rubber.

 

 

•   Remove the 2-by-4’s and lower the weight of the pump unit onto the shock-mounts.

  •   Tighten the nuts on the bottom of the shock-mounts until the shock-mounts just begin to bulge, and then tighten one full turn.
  •   Remove the straps holding hoses and power cords during shipment. Extend hoses and power cord behind and below the pump.
 

 

•   Remove the black oil fill shipping cap from the top of the pump and replace with the red vent cap attached to the pump head. 

Verify that the oil level in the pump is at the red dot on the oil level sight-glass. 

Water supply hose

: Connect the 6-foot braided 

water supply hose to the float valve. Connection is made at the underside of the pump frame-plate, beneath the blue float 

tank, to the threaded ball-cock fitting. 

DO NOT OVER-TIGHTEN.

 Over-tightening will twist the float valve in the tank causing 

the float to bind against the side of the tank. The supply end of the water supply hose will be connected to the water filter after 

it is installed.

7

Assembly and Installation

Figure 3 - SMT-1100W Front View 

Figure 4 - SMT-1100W Side View

Содержание SMT-1100W

Страница 1: ...rvice problem or need help please call our toll free number 1 800 548 3373 or 479 636 5776 TERMS All parts will be shipped with check in advance or C O D Commercial accounts are allowed 15 day terms f...

Страница 2: ...ard or recaptured water excessive hot water temperatures exceeding 120 Fahrenheit 49 Celsius using bleach as an injected chemical or using hydrogen peroxide as an injected chemical www spraymastertech...

Страница 3: ...resolved then please call our toll free customer service number 1 800 548 3373 or 479 636 5776 Service Requirements Water Flow minimum 5 GPM at 30 PSI Temperature 40 to 120 F maximum 125 F Electric SM...

Страница 4: ...alcohol or drugs Keep operating area clear of all persons Do not overreach or stand on unstable support Keep good footing and balance at all times Follow the maintenance instructions specified in the...

Страница 5: ...considerations will help to ensure the unit is properly installed in the best location with minimal difficulty Location Safety and convenience during use and servicing of the equipment should be a pri...

Страница 6: ...upply to the unit must have a flow rate of at least 5 GPM at a pressure of 30 PSI Anything less may cause intermittent shutdown of the system Water temperature Water supply temperatures in excess of 1...

Страница 7: ...rections in the instruction sheet provided with the hardware kit Loosely install the nuts on the shock mounts on the underside of the brackets These will be wrench tightened after the pump is secured...

Страница 8: ...onnected to the water supply bibb and the hose bibb valve is fully open Circuit Breaker main Set the circuit breaker in the main panel to the on position GFCI Connect the unit GFCI power cord to the d...

Страница 9: ...d to adjust the spray pattern from a wide angle spray to a zero degree stream Moving the black body of the nozzle toward or away from the gun handle respectively makes selection of high or low pressur...

Страница 10: ...y gun firmly Direct the spray gun nozzle away from individuals DANGER Electrocution Serious injury or death Do not spray energized electrical equipment or electrical outlets Set ON OFF switch to ON Di...

Страница 11: ...versely affect operation Pour 8 ounces of de liming agent into the full float tank With the spray gun connected and closed turn the pump ON and allow recirculation for 5 minutes After recirculation di...

Страница 12: ...to achieve the manufacturer s recommended chemical solution strength Example a 2 9 gallon per minute GPM pump used to apply a chemical requiring a mix ratio of 4 ounces per gallon will need to inject...

Отзывы: