SMT SMT-1100W Скачать руководство пользователя страница 5

ASSEMBLY AND INSTALLATION

GROUND FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION

This pressure washer is provided with a ground fault circuit interrupter (GFCI) built into the plug of the power supply cord. This device 

provides additional protection from the risk of electric shock. Should replacement of the plug or cord become necessary, use only 

identical replacement parts that include GFCI protection. Replace compete GFCI cord assembly if either the GFCI, plug or cord is 

damaged, frayed or worn.

GROUNDING

This product must be grounded. If it should malfunction or 

break down, grounding provides a path of least resistance 

for electric current to reduce the risk of electric shock. This 

product is equipped with a cord having an equipment-

grounding conductor and a grounding plug. The plug must 

be plugged into an appropriate outlet that is properly 

installed and grounded in accordance with all local codes and 

ordinances.

DANGER

 - Improper connection of the equipment-grounding 

conductor can result in a risk of electrocution. Check with a 

qualified electrician or service personnel if you are in doubt 

as to whether the outlet is properly grounded. Do not modify 

the plug provided with the product; if it will not fit the outlet, 

have a proper outlet installed by a qualified electrician. Do 

not use any type of adaptor with this product.

EXTENSION CORDS

Use only 3-wire extension cords that have 3-prong grounding-type 

plugs and 3-pole cord connectors that accept the plug from the 

product. Use only extension cords that are intended for outdoor 

use. These extension cords are identified by a marking "Acceptable 

for use with outdoor appliances; store indoors while not in use." Use 

only extension cords having an electrical rating not less than the 

rating of the product. Do not use damaged extension cords. Examine 

extension cord before using and replace if damaged. Do not abuse 

extension cords and do not yank on any cord to disconnect. Keep cord 

away form heat and sharp edges. Always disconnect the extension 

cord from the receptacle before disconnecting the product from the 

extension cord.

WARNING - To reduce the risk of electrocution, keep 

all connections dry and off the ground. Do not touch 

the plug with wet hands.

Planning The Installation

Prior to beginning the installation, thoroughly consider where the unit will be located, access to utilities and tool requirements for the 

job. These considerations will help to ensure the unit is properly installed in the best location with minimal difficulty.

 

 Location

 - Safety and convenience during use and servicing of the equipment should be a primary concern in determining the 

specific location of the SMT wall-mounted cleaning system. 

 

 Accessibility 

- A readily accessible unit will ensure that the cleaning will be done regularly and with less effort. Accessibility will also 

provide convenience when servicing becomes necessary. Avoid installing the unit in a location that will become inaccessible.

 

 Clearances

 - Adequate clearance overhead and on both sides is important. Fourteen-inch overhead clearance is required to remove 

the stainless steel cover. Ten-inch clearance is required on each side to remove the cover mounting hardware. Units equipped with 

a wall-mounted hose reel will require additional clearance on the right side for manually rewinding the hose.

 

 Structural  support

 - A fully assembled SMT wall-mount unit weights approximately 100 pounds. It is important for personal and 

equipment safety that the unit is securely fastened to a wall that will sustain this weight. Walls with metal framing should include 

backing for mounting the SMT unit.

 

 Safety

 - The unit should be mounted on the wall at a height that does not present a hazard of being struck by personnel or 

interfering with the flow of traffic in the area in which the unit is installed.

 

 Electrical

 - The SMT unit is equipped with a 4-foot long power cord. The unit or the power receptacle should be positioned such 

that the power cord can be easily connected to the receptacle with minimal strain on the cord. The power receptacle should be 

located above the SMT unit away from risk of exposure to water.

 

 Water

 - The SMT unit is equipped with a 6-foot water supply hose. The unit or the hose bib should be positioned such that the 

supply hose can be easily connected with minimal stress on the hose.

 

 Noise

 - As with all pressure washers, the SMT unit will make noise during operation. Avoid locating the unit in or adjoining any area 

that is noise sensitive.

 

 Chemical  Supply

 - The SMT unit can draw chemical from a 1-gallon bottle mounted on the wall or a 55-gallon drum. Ensure 

adequate chemical storage space if chemical(s) will be drawn from a large container.

WARNING: 

 

Unit is to be installed in a location designed for wet applications with an operable and adequate drain.  If installation in such a 

location is not possible, turn off the incoming water supply to the unit when unattended or not in use to minimize the possibility of 

leaks and potential water damage.

5

Содержание SMT-1100W

Страница 1: ...rvice problem or need help please call our toll free number 1 800 548 3373 or 479 636 5776 TERMS All parts will be shipped with check in advance or C O D Commercial accounts are allowed 15 day terms f...

Страница 2: ...ard or recaptured water excessive hot water temperatures exceeding 120 Fahrenheit 49 Celsius using bleach as an injected chemical or using hydrogen peroxide as an injected chemical www spraymastertech...

Страница 3: ...resolved then please call our toll free customer service number 1 800 548 3373 or 479 636 5776 Service Requirements Water Flow minimum 5 GPM at 30 PSI Temperature 40 to 120 F maximum 125 F Electric SM...

Страница 4: ...alcohol or drugs Keep operating area clear of all persons Do not overreach or stand on unstable support Keep good footing and balance at all times Follow the maintenance instructions specified in the...

Страница 5: ...considerations will help to ensure the unit is properly installed in the best location with minimal difficulty Location Safety and convenience during use and servicing of the equipment should be a pri...

Страница 6: ...upply to the unit must have a flow rate of at least 5 GPM at a pressure of 30 PSI Anything less may cause intermittent shutdown of the system Water temperature Water supply temperatures in excess of 1...

Страница 7: ...rections in the instruction sheet provided with the hardware kit Loosely install the nuts on the shock mounts on the underside of the brackets These will be wrench tightened after the pump is secured...

Страница 8: ...onnected to the water supply bibb and the hose bibb valve is fully open Circuit Breaker main Set the circuit breaker in the main panel to the on position GFCI Connect the unit GFCI power cord to the d...

Страница 9: ...d to adjust the spray pattern from a wide angle spray to a zero degree stream Moving the black body of the nozzle toward or away from the gun handle respectively makes selection of high or low pressur...

Страница 10: ...y gun firmly Direct the spray gun nozzle away from individuals DANGER Electrocution Serious injury or death Do not spray energized electrical equipment or electrical outlets Set ON OFF switch to ON Di...

Страница 11: ...versely affect operation Pour 8 ounces of de liming agent into the full float tank With the spray gun connected and closed turn the pump ON and allow recirculation for 5 minutes After recirculation di...

Страница 12: ...to achieve the manufacturer s recommended chemical solution strength Example a 2 9 gallon per minute GPM pump used to apply a chemical requiring a mix ratio of 4 ounces per gallon will need to inject...

Отзывы: