Hardware and Tool Requirements

 

 Mounting  hardware

 - Hardware for mounting to wood studs is included with your unit. This hardware may not be suitable for 

many  other type walls. Do not use hardware that is inadequate for your installation application.

 

 Tools and supplies 

- No special tools are required. Installation of this unit can be done with tools that are common to the average 

service technician’s toolbox or are available at your local hardware store. Installation of the pump unit will be made easier and 

safer with the use of two 24-inch 2-by-4’s. These 2-by-4’s will be laid across the wall-mount brackets to support the pump during 

installation of vibration dampening mounts.

Utilities

 

 Electrical

 - Verify the dedicated circuit Voltage is correct for the Voltage of the unit being installed. Make sure the unit ON/OFF 

switch is set to “OFF" prior to connecting the unit to the power receptacle.

 

 Water pressure and flow rate - The water supply to the unit must have a flow rate of at least 5 GPM at a pressure of 30 PSI. Anything 

less may cause intermittent shutdown of the system.

 

 Water  temperature

 - Water supply temperatures in excess of 120° F will cause the unit to shut down to protect the pump seals from 

damage. SMT recommends a water supply temperature of 120° F or less.

Installation Procedure

 

Refer to Figure 1 and Figure 2 for installation of the SMT600-W.

6

Assembly and Installation

WATER SUPPLY
BELOW UNIT
40

°

F-120

°

F RECOMMENDED

125

°

F MAXIMUM

4 GPM @ 30PSI

Figure 1 - SMT 600W Front View 

Figure 2 - SMT 600W Side View

SIDE VIEW

ARCHITECTURAL DRAWING,

ASSEMBLED PRODUCTS CORPORATION

ROGERS, AR. 72756

TM

TM

SMT

12/10/07

TS

SMT 600W

Ceiling

16"

36"

32"

12" min

17"

14 1/4

12"

14" min

Ceiling

20 3/16

14" min

1 1/2"

1 1/2"

20 3/16"

17"

FRONT VIEW

TOP VIEW

ELECTRICAL SUPPLY
REQUIRED ABOVE UNIT

4' X 8', 3/4 PLYWOOD BACKING

48"

ACD-600W

System Requirements:

115V/20A Dedicated Circuit and/or 208V/230V, 15AMP, W 15-20 AMP Receptacle, Nema 5-20R or 6-15R (Rated for wet application)

4' x 8', 3/4" Backing  Required in studded walls

Ambient Water Supply- Max Temp. 120 Deg. F., 5 Gpm @ 30 Psi with 3/4" Hose Bib (One For Each Unit) 

NOTE: Electrical, Water, and Backing are not supplied by SMT

C

A

P

CHG

ECN#

DESCRIPTION OF CHG

DATE

BY

REL#

BY

DATE:

SCALE:

DATE:

USED ON:

DRWN BY:

CHKD BY:

PART NO.:

TITLE:

MATRL:

Содержание SMT-1100W

Страница 1: ...rvice problem or need help please call our toll free number 1 800 548 3373 or 479 636 5776 TERMS All parts will be shipped with check in advance or C O D Commercial accounts are allowed 15 day terms f...

Страница 2: ...ard or recaptured water excessive hot water temperatures exceeding 120 Fahrenheit 49 Celsius using bleach as an injected chemical or using hydrogen peroxide as an injected chemical www spraymastertech...

Страница 3: ...resolved then please call our toll free customer service number 1 800 548 3373 or 479 636 5776 Service Requirements Water Flow minimum 5 GPM at 30 PSI Temperature 40 to 120 F maximum 125 F Electric SM...

Страница 4: ...alcohol or drugs Keep operating area clear of all persons Do not overreach or stand on unstable support Keep good footing and balance at all times Follow the maintenance instructions specified in the...

Страница 5: ...considerations will help to ensure the unit is properly installed in the best location with minimal difficulty Location Safety and convenience during use and servicing of the equipment should be a pri...

Страница 6: ...upply to the unit must have a flow rate of at least 5 GPM at a pressure of 30 PSI Anything less may cause intermittent shutdown of the system Water temperature Water supply temperatures in excess of 1...

Страница 7: ...rections in the instruction sheet provided with the hardware kit Loosely install the nuts on the shock mounts on the underside of the brackets These will be wrench tightened after the pump is secured...

Страница 8: ...onnected to the water supply bibb and the hose bibb valve is fully open Circuit Breaker main Set the circuit breaker in the main panel to the on position GFCI Connect the unit GFCI power cord to the d...

Страница 9: ...d to adjust the spray pattern from a wide angle spray to a zero degree stream Moving the black body of the nozzle toward or away from the gun handle respectively makes selection of high or low pressur...

Страница 10: ...y gun firmly Direct the spray gun nozzle away from individuals DANGER Electrocution Serious injury or death Do not spray energized electrical equipment or electrical outlets Set ON OFF switch to ON Di...

Страница 11: ...versely affect operation Pour 8 ounces of de liming agent into the full float tank With the spray gun connected and closed turn the pump ON and allow recirculation for 5 minutes After recirculation di...

Страница 12: ...to achieve the manufacturer s recommended chemical solution strength Example a 2 9 gallon per minute GPM pump used to apply a chemical requiring a mix ratio of 4 ounces per gallon will need to inject...

Отзывы: