SERIES 28RTS/HE BOILER INSTALLATION AND OPERATION INSTRUCTIONS

c)   Insofar as is practical, close all building doors and 

windows and all doors between the space in which 
the appliances remaining connected to the common 
venting system are located and other spaces of the 
building. Turn on clothes dryers and any appliance 
not connected to the common venting system. Turn 
on any exhaust fans, such as range hoods and 
bathroom exhaust, so they will operate at maximum 
speed. Do not operate a summer exhaust fan for a 
boiler installation. Close fi replace dampers.

 

Dans la mesure du possible, fermer toutes les 
portes et les fenêtres du bâtiment et toutes les 
portes entre l'espace où les appareils toujours 
raccordés du système d'évacuation sont installés 
et les autres espaces du bâtiment.  Mettre en 
marche les sécheuses, tous les appareils non 
raccordés au système d'évacuation commun et 
tous les ventilateurs d'extraction comme les hottes 
de cuisinère et les ventilateurs des salles de 
bain. S'assurer que ces ventilateurs fonctionnent 
à la vitesse maximale. Ne pas faire fonctionner 
les ventilateurs d'été. Fermer les registres des 
cheminées.

d)   Place in operation the appliance being inspected. 

Follow the lighting instructions. Adjust thermostat so 
appliance will operate continuously.

 

Mettre l'appareil inspecté en marche. Suivre les 
instructions d'allumage. Régler le thermostat de 
façon que l'appareil fonctionne de façon continue. 

e)   Test for spillage at the draft hood relief opening after 

5 minutes of main burner operation. Use the fl ame 
of a match or candle, or smoke from a cigarette, 
cigar or pipe.

 

Faire fonctionner le brûleur principal pendant 5 min 
ensuite, déterminer si le coupetirage déborde à 
l'ouverture de décharge. Utiliser la fl amme d'une 
allunette ou d'une chandelle ou la fumée d'une 
cigarette, d'un cigare ou d'une pipe.

Always provide a minimum clearance of 6 in.152 mm 
between single wall metal vent pipe and all combustible 
materials. 

WARNING: Failure to maintain minimum 
clearances between vent connectors and any 
combustible material can result in a fi re causing 
extensive property damage, severe personal 
injury or death!

COMMON VENT SYSTEMS

If an existing boiler is removed from a common venting 
system, the common venting system may then be too 
large for the proper venting of the remaining appliances 
connected to it. At the time of removal of an existing 
boiler, the following steps shall be followed with each 
appliance remaining connected to the common venting 
system placed in operation, while the other appliances 
remaining connected to the common venting system are 
not in operation.

Au moment du retrait d'une chaudière existante, les 
mesures suivantes doivent être prises pour chaque 
appareil toujours raccordé au système d'évacuation 
commun et qui fonctionne alors que d'autres appareils 
toujours raccordés au système d'évacuation ne 
fonctionnent pas: système d'évacuation

a)   Seal any unused openings in the common venting 

system. 

 

Sceller toutes les ouvertures non utilisées du 
système d'évacuation.

b)   Visually inspect the venting system for proper size 

and horizontal pitch and determine there is no 
blockage or restriction, leakage, corrosion and other 
defi ciencies which could cause an unsafe condition.

 

Inspecter de façon visuelle le système d'évacuation 
pour déterminer la grosser et l'inclinaison horizontale 
qui conviennent et s'assurer que le système est 
exempt d'obstruction, d'étranglement de fruite, 
de corrosion et autres défaillances qui pourraient 
présenter des risques.

Содержание SERIES 28RTS/HE

Страница 1: ...ier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WESTCAST INC 260 NORTH ELM STREET WESTFIELD MA 01085 TEL 413 562 963...

Страница 2: ...assembled block or as complete factory assembled packaged boilers All boiler components should be inspected for damage upon receipt Any damage should be immediately reported to the trucker or wholesa...

Страница 3: ...nsive property damage severe personal injury or death BOILER RATINGS CAPACITIES Before undertaking the installation of the RTS Series boiler check the boiler rating plate to ensure that the boiler has...

Страница 4: ...200 7733 3600 23 227 3800 950 6129 1267 8162 3800 24 518 4000 1000 6452 1334 8592 4000 25 808 4200 1050 6775 1400 9022 4200 27 098 4400 1100 7097 1467 9451 4400 28 389 4600 1150 7420 1533 9881 4600 29...

Страница 5: ...spection of the chimney must be performed Ensure that the chimney is clean properly constructed lined and properly sized see Figure 2 Table 2 lists the equivalent breeching and flue sizes required for...

Страница 6: ...the boiler s smoke hood This includes the removal or alteration of any baffles Never install a vent pipe of a diameter smaller than that of the boiler smoke hood outlet Failure to comply with this wa...

Страница 7: ...n ensuite d terminer si le coupetirage d borde l ouverture de d charge Utiliser la flamme d une allunette ou d une chandelle ou la fum e d une cigarette d un cigare ou d une pipe Always provide a mini...

Страница 8: ...31 Installation of Oil Burning Equipment for oil burners Si la grosseur d une section du syst me d vacuation doit tr modifi e le syst me devrait tr modifi pour respecter les valeurs minimales des tabl...

Страница 9: ...Never leak test the boiler using compressed air Failure to comply with this warning may result in property damage severe personal injury or death 1 Plug all openings in the boiler and fill it with wat...

Страница 10: ...on draw rod and washer coating thread and washer on one end only Torque the draw rods from the end with anti seize washer Follow the steps as described below Do not completely tighten one side gradua...

Страница 11: ...efficiency 28RTS HE comes with design certified heat transfer rod sets Each tube of 15 heat transfer rods will baffle one flue In order to obtain the high efficiency for which the boiler was designed...

Страница 12: ...ut cover and tighten the nuts to 15 ft lbs 21 Nm 6 Apply a bead of high temperature silicone caulk around the perimeter of the cleanout cover to ensure an air tight seal Figure 10 Cleanout Cover Assem...

Страница 13: ...xpansion pin item 7 through the hinge bosses to secure the door to the cover 3 Insert the hex bolt item 6 through the hole in the observation port cover 4 Install the spring nut and knob items 3 2 1 o...

Страница 14: ...mokehood Installation Figure 13 1 Screw the four 5 16 18 x 1 1 2 in studs into the tapped holes around the smokehood opening in the back section 2 Apply smokehood insulation tape to smokehood 3 Place...

Страница 15: ...arrangement for multiple heaters Burner Mounting 1 Clean the burner mounting flange to remove any rust or debris 2 Install the four 3 8 in x 1 1 4 in studs into the tapped holes in the burner mounting...

Страница 16: ...Never use automotive antifreeze in the boiler or heating system If antifreeze is necessary it must be formulated specifically for hydronic heating systems such as ethylene or propylene glycol Failure...

Страница 17: ...nstallation NOTE Install the smoke hood before proceeding 1 Install 3 in x 4 in NPT bushings in the two 4 in NPT tappings at the bottom of the back section Install two 3 in NPT x 3 in nipples with bal...

Страница 18: ...gure 21 RTS Installation Figure 23 RTS Installed IMPORTANT NOTE A removable elbow or section of pipe must be attached to the Back Section return port to allow for RTS removal should maintenance be req...

Страница 19: ...sonal injury or death Control Installation Locate the temperature pressure gage low water cutoff high limit and operating controls per Figures 17 24 and Table 5 Optional controls must be installed in...

Страница 20: ...TE Some locations do not allow this solution to be used Check with the local authority having jurisdiction 4 Mix the cleaning chemicals with water to create a concentrated solution Pour the cleaning s...

Страница 21: ...maximum trace of smoke The flue gas samples should be taken at the smoke hood Confirm proper burner adjustment with a calibrated combustion analyzer BURNER INSTALLATION WARNING The burner must be ins...

Страница 22: ...ver exceed the maximum set point of 240 F 116 C The aquastat high limit cannot be repaired If it fails to function properly replace it CAUTION If the flue gas temperature exiting the smoke hood is les...

Страница 23: ...ulation and rope seal If damaged or deteriorated replace them 10 Install the clean out covers and reseal them with a silicone caulk rated for 500 F 260 C 11 Install the left jacket panels and remount...

Страница 24: ...Page 24 SERIES 28RTS HE BOILER INSTALLATION AND OPERATION INSTRUCTIONS Figure 25 Boiler Assembly SIOM 161 Rev 1...

Страница 25: ...let Increaser 16 to 18 69904 1 1 Smoke Hood Assembly 10 70633 1 1 1 16 1 Smoke Hood Assembly 12 70611 1 1 Smoke Hood Assembly 14 70612 1 1 1 1 1 Smoke Hood Assembly 16 70613 1 1 1 1 1 16a Smokehood in...

Страница 26: ...nsulating Block 69645 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 34 Burner Mounting Plate Rope Seal 1 4 x 7 60026 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 n s Can of Spray Adhesive 70492 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 n s Flu...

Страница 27: ...nting system pipes or chimney escaping into the living space Flames coming out around the appliance Yellow colored flames in the appliance Stale or smelly air The presence of soot or carbon in or arou...

Страница 28: ...WESTCAST INC 260 NORTH ELM STREET WESTFIELD MA 01085 TEL 413 562 9631 FAX 413 562 3799 In Canada 7555 Tranmere Drive Mississauga Ont L5S 1L4 905 670 5888 Fax 905 670 5782...

Отзывы: