Instruction for the installer
33
3.3
Burner and nozzle characteristics table (90 cm. models)
Burner
Rated
heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1
50
30
350
73
71
Semi-rapid
1.75
65
33
450
127
125
Rapid
3
85
45
800
218
214
Triple crown
3.2
91
65
1500
233
229
Fish pan
1.9
68
45
800
138
136
Oven
3.2
87
48
850
233
229
Maxi oven
5.2
110
59
1200
378
371
Grill
2.9
87
//
//
218
214
Maxi grill
4.0
100
//
//
291
286
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary
1
72
350
Semi-rapid
1.75
97
450
Rapid
3
115
800
Triple crown (4)
3.5
133
1500
Triple crown (8)
3.5
140
1500
Fish pan
1.9
94
800
Oven
3.2
130
850
Maxi oven
5.2
164
1200
Grill
2.9
130
//
Maxi Grill
4.0
150
//