Instruction for the installer
32
3.2
Burner and nozzle characteristics table (60 cm. models)
Burner
Rated
heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1.0
50
30
350
73 71
Semi-rapid
1.75
65
33
450
127 125
Rapid (3)
3.0
85
45
800
218 214
Rapid (5)
2.3
75
45
800
167 164
Triple crown
3.2
91
65
1500
233 229
Oven
3.2
87
48
850
233 229
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary
1.0
72
350
Semi-rapid
1.75
97
450
Rapid (3)
3.0
115
800
Rapid (5)
2.3
103
800
Triple crown
3.5
133
1500
Oven
3.2
130
850