-21-
No. JXC
※
-OMY0008
(
PC is prepared by the user.
)
(2) Connection with a PC
Caution
(1) Do not connect any device other than the specified device (JXC-W2/W2A-C, LEC-W2/W2A-C,
LEC-T1).
If connected to other equipment, this product may be damaged due to differences in signal wiring.
(2) When connecting cables, do not allow conductors to get caught in the connector insertion port.
5.4 IN, OUT: EtherCAT communication connector
E.g.) Example for a connection of the daisy chain
The standard Ethernet cable with CAT5 or higher and 100BASE-TX and PLC need to be prepared by the
user.
Connect the “IN” connector to the upper side device (PC, PLC, etc.), and connect the “OUT” connector
to the lower side device.
Follow the topology of EtherCAT communication for details.
EtherCAT
Master (PLC)
IN
OUT
IN
OUT
IN
OUT
Standard Ethernet cable
(C
JXCEH Controller
JXCEH Controller
JXCEH Controller
Controller
SI
PC
USB cable
(A-miniB type)
Communication cable
When using the LEC-W2, it is necessary
to connect a conversion unit (P5062-5) to
the communication cable.