Switch Point Setting
It is possible to change OUT1: switch point and OUT2: pressure set value/switch point.
OUT2 is set to pressure setting mode (pressure detection mode) as a default. When changing to switch point
setting mode (distance setting mode), set in the function selection mode (page
).
■
Default settings of OUT1 (hysteresis mode, reversed output setting)
Refer to the figure below for the default settings of OUT1.
ISA3-F
ISA3-G
ISA3-H
The switch output turns ON when the display value is less than switch point. (Solid line in the chart)
The switch output turns OFF when the display value is greater than the switch point added to the hysteresis
value. (Dashed line in the chart)