○SUP port (supply port)
Use the correct tightening torque. Refer to the following table for the appropriate tightening torque.
Fit the seal plug (supplied with the product) to the unused port.
Product
Nominal
thread size
Proper tightening
torque (Nm)
Product
Nominal
thread size
Proper tightening
torque (Nm)
ISA3
Rc1/8
G1/8
3 to 5
Regulator
Rc1/4
G1/4
8 to 12
○OUT port (detection port)
Use the correct tightening torque. Refer to the following table for the appropriate tightening torque.
Nominal
thread size
Proper tightening
torque (Nm)
G1/8
3 to 5
For ø4 one-touch fitting, use tube with O.D. 4 mm, and I.D. 2.5 mm.
For ø6 one-touch fitting, use tube with O.D. 6 mm, and I.D. 4 mm.
Warning
Do not use equipment or fittings that may leak or obstruct the air flow between the
product and the detection nozzle.
The product should be positioned higher than the detection nozzle.
If the product is positioned lower than the detection nozzle, water or oil may enter the detection port, causing a malfunction or
operational failure.
Содержание ISA3-F series
Страница 1: ...No PS OMW0009 A PRODUCT NAME Digital Gap Checker compatible MODEL Series Product Number ISA3 series ...
Страница 10: ...2 About this product 9 No PS OMW0009 A With control unit ...
Страница 23: ...2 About this product 22 No PS OMW0009 A ISA3 Without control unit DIN rail mounting ...
Страница 24: ...2 About this product 23 No PS OMW0009 A ISA3 B L1 3 5 7 With control unit Bracket mounting ...
Страница 25: ...2 About this product 24 No PS OMW0009 A ISA3 B R1 3 5 7 ISA3 B R0 2 4 6 8 ISA3 B LN ISA3 B RN ...
Страница 42: ...3 Installation 41 No PS OMW0009 A Part structure Without control unit ...
Страница 43: ...3 Installation 42 No PS OMW0009 A With control unit Supply port Left side ...
Страница 44: ...3 Installation 43 No PS OMW0009 A With control unit Supply port Right side ...
Страница 115: ...5 Troubleshooting 114 No PS OMW0009 A Relationship between supply pressure and display ...