![SMC Networks EX600-ED Series Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/smc-networks/ex600-ed-series/ex600-ed-series_operation-manual_1299354071.webp)
-70-
No.EX##-OMN0030-A
•Digital Input Unit object (Class:6Ah) [
DeviceNet
TM
extended object library 1]
Instance
Attribute
Access
Name
Type
Value
70h Get/Set
Monitoring short circuit at Power
Supply
BOOL
0=Disable
1=Enable
78h
Get/Set Inrush current detection
BOOL
0=Disable
1=Enable
A4h
Get/Set Input filtering time
USINT
0=0.1 ms
1=1.0 ms
2=10 ms
3=20 ms
01h to 40h
A8h
Get/Set Input extension time
USINT
0=1.0 ms
1=15 ms
2=100 ms
3=200 ms
•Digital Output Unit object (Class:6Bh) [
DeviceNet
TM
extended object library 1]
Instance
Attribute
Access
Name
Type
Value
71h
Get/Set Monitoring short circuit at Output
BOOL
0=Disable
1=Enable
01h to 40h
7Bh
Get/Set Restart after short circuit
BOOL
0=Manual
1=Auto
•SI Unit object (Class:6Ch) [
DeviceNet
TM
extended object library 1]
Instance
Attribute
Access
Name
Type
Value
71h
Get/Set Monitor short circuit at Output
BOOL
0=Disable
1=Enable
7Bh
Get/Set Restart after short circuit
BOOL
0=Manual
1=Auto
ACh Get/Set
Control power supply voltage
monitor
BOOL
0=Disable
1=Enable
01h to 10h
ADh Get/Set
Output power supply voltage
monitor
BOOL
0=Disable
1=Enable