-44-
No.EX##-OMN0030-A
•SI unit parameters
Parameter
setting
No.
Parameter
(H.T. Symbol)
Definition
Item
Content
Default
setting
By
EDS
By
H.T.
Enable Generates
an
error.
○
1
Power supply
for control and
input voltage
monitor
(PWRC_Mon)
Generated error
per unit when
control and input
power supply
voltage goes over
approx. 26V or
under 21V.
Disable
Does not generate an
error.
○
○
Enable
Generates an error.
○
2
Power supply
for output
voltage
monitor
(PWRO_Mon)
Generated error
per unit when
output power
supply voltage
goes over approx.
26V or under 20 V.
Disable
Does not generate an
error.
○
○
Enable
Generates an error.
○
3
Short Circuit
Detection
(SC_MonOp)
Generates error
per unit when the
short circuit of the
valve is detected.
Disable
Does not generate an
error.
○
○
Auto
Error is automatically
cleared when the short
circuit is fixed.
○
4
Restart after
short circuit
(SC_RstOp)
Restore the setting
of short circuit
detection error per
unit after the valve
short circuit is
cleared.
Manual
Even when the short
circuit is fixed, error is not
cleared until the power is
supplied again.
○
○
Enable
Generates an error.
5
Open Circuit
Detection
(OC_Mon)
Generates error
per channel when
the disconnection
of the valve is
detected.
Disable
Does not generate an
error.
○
∆
∗
5
○
Clear
Turn off the output.
○
Hold
Hold the output.
6
Output setting
during
communication
fault
∗
1
(Fault_MD )
Set output per
channel when
communication is
abnormal.
ForceON
Turn on the output
forcefully.
∆
∗
5
○
Clear
Turn off the output.
○
Hold
Hold the output.
7
Output setting
during
communication
idling
∗
1
∗
2
(Idle_MD )
Set output per
channel during
communication
idling
ForceON
Turn on the output
forcefully.
∆
∗
5
○