7
o
Use the Up / Down Arrow keys and move the asterix to
MISC
and press the enter key.
o
BYPASS TERM LIMITS
should be the first item listed. If it’s
not there use the Up / Down Arrow keys and move the
asterix to
BYPASS TERM LIMITS
and press the enter key.
o
Use the Up / Down Arrow keys to change the word
“NO”
to “
YES
”.
o
Use the RIGHT Arrow key and move the asterix under the
word “SAVE” and press enter.
o
Hit the LEFT Arrow (ESC) button several times to get to the
MAIN SCREEN
.
Verify the LCD displays “Construction” Mode on the
MAIN
SCREEN
.
Verify that the Magnetek drive is not showing a “Setup Fault One”
on the display.
o
Go to “
Troubleshooting – Setup Fault One
” for corrective
actions.
SETUP
Local Outputs
Security
*Misc
MISC
*Bypass Term Limits
Emergency Power
Monitor BPS
BYPASS TERM LIMITS
NO
*
BYPASS TERM LIMITS
YES
Save
*