APC615 Pump Unit Controller User Manual
APC615 Pump Unit Controller Version 1.0 2017-10-20 Page 39 of 54
8
PARAMETERS SETTING
After controller is powered up, hold and press
for 3s to enter into
“Parameter Configure”
menue, and menue items are as follows,
Select
“Parameter Config.” Item to enter into parameters setting screen after entering the correct
password (default 00318).
Detailed parameters setting methold is as below,
Parameter Config.
Screen 1: Use
,
to scroll settings,
to enter settings
(Screen 2), and press
to go back. Choose
“Return” and press
“Confirm” key to return to the previous level.
>Return
>Timers
>Engine
>Module
Timers
Screen 2: Use
,
to scroll settings,
to enter settings
(Screen 3), and press
to go back (Screen 1). Choose
“Return”
and press
“Confirm” key to return to the previous level (Screen 1).
>Return
>Start Delay
>Return Delay
>Preheat Delay
Start Delay
Screen 3: Pressing
to shift cursor to select the digit that to be
configured, and change the digit through pressing
or
. After
the parameter is setting completed, press
to save it, and then
press
“Down” key to return to the previous level (Screen 2)
0000
1
s
Timers
Screen 4: Pressing
to select target item, and the setting methold
is the same as Screen 2 and Screen 3
>Return
>Start Delay
>Return Delay
>Preheat Delay
Over Shutdown
Screen 5: Setting sensor shutdown parameters. Choose
“Over
Shutdown
Setting” and press
enters into parameter setting page.
Then press
again, controller displays interface of screen 5.
Pressing
or
to select the item that need to be configured,
and pressing
to save it, meanwhile, cursor shifts down and
controller displays screen 6 as below.
Enable Choose: Enable
SetVal: +00098
DelayVal: 00003s
>Return
>Parameter Config.
> Language
>Event Log
>Module Info