Functional Description
RTM-ATCA-F125 Installation and Use (6806800K30J)
41
4.4.2
Front-Blade Port Mapping
The eight SFP+ sites are connected through phys to the front blade base and fabric
switches according to the following table.
4.4.3
BCM8747 Configuration Flash
The BCM8747 requires an external SPI Flash to store microcode for the internal
microcontroller. A single SPI Flash is connected to the FPGA and the SPI buses from each
BCM8747 are similarly connected to the FPGA. Register settings in the FPGA allow either
BCM8747 to connect to the SPI Flash as well as providing a programming port.
4.4.4
Transmitter Control
The TXONOFF signals on each BCM8747 are connected together to the RTM FPGA which
allows them to be driven under software control. This enables software to enable and
disable the SFP+ optical outputs.
4.4.5
BCM8747 Status
The PCMULK, PCDRLK, PLOSB and LASI signals from each BCM8747 port are
connected to the RTM FPGA to allow them to be monitored by software. The PLOSB and
LASI signals can also generate an interrupt to the front-blade. Refer to
Table 4-6
10Gbps SFP+ Front-Board Mapping
RTM Port
Front Blade Base Switch
Front Blade Fabric Switch
ETH5
xe1
n/a
ETH6
xe0
n/a
ETH7
n/a
xe11
ETH8
n/a
xe10
ETH9
n/a
xe19
ETH10
n/a
xe18
ETH11
n/a
xe17
ETH12
n/a
xe16
Содержание 6806800K30J
Страница 1: ...RTM ATCA F125 Installation and Use P N 6806800K30J November 2020...
Страница 6: ...List of Figures 6 RTM ATCA F125 Installation and Use 6806800K30J...
Страница 8: ...List of Tables 8 RTM ATCA F125 Installation and Use 6806800K30J...
Страница 24: ...24 RTM ATCA F125 Installation and Use 6806800K30J Introduction Introduction...
Страница 48: ...48 RTM ATCA F125 Installation and Use 6806800K30J Related Documentation Related Documentation...
Страница 49: ...1...