-11-
Setting Limits – Dual Leaf Gate
Dual Motor Installation
1.
Press MENU for 3 secs to enter parameter set up.
The display will show
Single Motor
(default).
Press MENU to cycle through to
Dual Motor
.
Press MODE save and exit to main screen.
2.
Press SET for 3 secs to enter set up mode.
The display will show Motor 1 (the master which
has the controller on board) as
Right Hand
Installation
(default). If this is correct press
SET to confirm (Fig. 17). If the master drive unit is
on the left side (when standing inside the driveway
looking out), press MENU to change to
Left Hand
then press SET to confirm .
Note:
Make sure that limit cams are installed and in the
desired open and closed positions.
1.
With the gate leafs open approximately half way,
make sure that the drive motors are engaged.
2.
Press PB or Transmitter Button 1.
Motor 1 will open the gate (at half speed) until it
reaches the open limit switch.
Then Motor 2 will open the second gate leaf (at half
speed) until it reaches the open limit switch.
Then Motor 1 will close the gate until the closed limit
is reached followed by Motor 2.
3.
The gate will now automatically measure time, current
and force margin required to close and open. It will
open (at half speed), then close (at full speed), then
open again and return to the closed position.
4.
Display will show
Set Up Complete
(Fig. 20).
After 5 seconds the display will will change to normal
operation mode (Fig. 15).
Aborting Limits Set Up
To abort limits set up whilst in progress – press MODE.
To return to set up mode press SET for 3 secs and repeat
initialising procedure as per above.
Resetting Limits
If you are not happy with the limits positions – reposition
the limit cams, then press SET again for 3 secs and
repeat initialising procedure as per above.
Dual Motor
Drive Motor 1
Set Up
Fig. 16
Fig. 18
Set Up
Complete
Fig. 20
Right Hand
Installation
Fig. 17
Drive Motor 2
Set Up
Fig. 19
Содержание Smart Slider
Страница 18: ... 18 Notes ...
Страница 19: ... 19 Notes ...