-10-
Motor 1
Set Up
Set Up
Complete
Gate
Closed
Setting Motor Installation
1.
Press SET for 3 secs to enter set up. The display will
show
Right Hand Installation
(default).
If this is correct (when standing inside the driveway
looking out) press SET to confirm. Otherwise press
MENU to change to
Left Hand
, then press SET
to confirm (Fig. 12). The display will show
Motor 1
Set Up
(Fig. 13).
Note:
Make sure that limit cams are installed and in the
desired open and closed positions.
Setting Limits
1.
With the gate open approximately half way, make sure
that the drive motor is engaged.
2.
Press PB or Transmitter Button 1.
The gate will automatically open (at half speed) until
it reaches the open limit switch. It will then close
automatically until the closed limit is reached.
3.
The gate will now automatically measure time, current
and force margin required to close and open. It will
open then close (at full speed), then open again and
return to the closed position.
4.
Display will show
Set Up Complete
(Fig. 14).
After 5 seconds the display will will change to normal
operation mode (Fig. 15).
Aborting Limits Set Up
To abort limits set up whilst in progress – press MODE.
To return to set up mode press SET for 3 secs and repeat
initialising procedure as per above.
Resetting Limits
If you are not happy with the limits positions – reposition
the limit cams, then press SET again for 3 secs and
repeat initialising procedure as per above.
Setting Limits – Single Leaf Gate
Fig. 13
Fig. 14
Fig. 15
Right Hand
Installation