ASSEMBLY/REPLACEMENT OF THE POWER SUPPLY CABLE
■
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
The electric cable must be kept locked to the terminal box by the cable fix, so that it
cannot come out. Connect the line cable to terminal
L
, the neutral cable to terminal
N
and the yellow/green cable to the earth terminal . The yellow/green cable must be
longer than the other two by at least 20 mm.
Ensure the electric cable does not pass near or come into contact with the surfaces
reaching a temperature above 75°C.
■
EARTH CONNECTION
■
Installation, connection and earthing of the electric system must comply with the
European standard requisites and meet the provisions of the local Standards in force.
This household appliance requires an earthing connection for protection against
short-circuits or electric dispersions. It must, therefore, be connected to an
appropriate electric socket.
The earth cable must not be interrupted by the switch.
ATTENTION:
DISCONNECT THE ELECTRIC POWER SUPPLY BEFORE PERFORMING
TECHNICAL ASSISTANCE OR MAINTENANCE ON THE PRODUCT.
In case of replacement of the electric cable, ensure the use of an electric cable certified
according to the Standards in force and suitable to the technical features of the product.
Use only flexible cables:
cable type H05RR-FH 3 x 1.5
for mod. FI TWIN use cable type H05RR-FH 3 x 2.5